JACKSONVILLE, FL —
OSHA Inspection: HOMEGUARD PRODUCTS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of HOMEGUARD PRODUCTS, INC. in 5430 SHAWLAND ROAD, JACKSONVILLE, FL 32254 (NAICS 323111). OSHA activity number 342295730.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HOMEGUARD PRODUCTS, INC.
- Site address
- 5430 SHAWLAND ROAD
- City
- JACKSONVILLE
- State
- FL
- ZIP
- 32254
- Mailing
- 5430 SHAWLAND ROAD, JACKSONVILLE, FL 32254
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323111
- Employees
- 15
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.28 B01 I
- Issued
- Aug 3, 2017
- Abate by
- Aug 29, 2017
- Penalty
- Initial $5,577 · Current $3,346 Reduced
General-duty citation text
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following: Guardrail systems, safety net systems, or personal fall arrest systems: a. On or about April 27, 2017, employees were on top of the wide web printing press cleaning without the use of any fall protection systems, being exposed to a 10-foot fall hazard.
Recent events (2)
- — I (S) $3346.2
- — Z (S) $5577
1910.147 C06 I
- Issued
- Aug 3, 2017
- Abate by
- Aug 29, 2017
- Penalty
- Initial $3,984 · Current $2,390 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a. On or about May 1, 2017, employees servicing and maintaining equipment, such as but not limited to the wide web press and re-wind machines, were exposed to hazards resulting from the unexpected release of stored energy. The employer had not conducted a periodic inspection of the energy control procedures at least annually to ensure the procedures were followed.
Recent events (2)
- — I (S) $2390.4
- — Z (S) $3984
1910.147 C06 II
- Issued
- Aug 3, 2017
- Abate by
- Aug 29, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: a. On or about May 1, 2017, employees servicing and maintaining equipment, such as but not limited to the wide web press and re-wind machines, were exposed to hazards resulting from the unexpected release of stored energy. The employer had not certified that a periodic inspection of the energy control procedures had been conducted at least annually to ensure the procedures were followed.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 D04 I
- Issued
- Aug 3, 2017
- Penalty
- Initial $5,577 · Current $3,346 Reduced
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a. On or about May 1, 2017, authorized employees performed service maintenance and cleaning of rollers on the Wilson Super Flexo wide web printer press and had not affixed their lockout tagout locks and devices to prevent release of stored energy sources, being exposed to amputation hazards from unexpected machine start up.
Recent events (2)
- — I (S) $3346.2
- — Z (S) $5577
More inspections at Homeguard Products, INC.
View Homeguard Products, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 323111)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342295730.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.