LAKEWOOD, NJ —
OSHA Inspection: MASTERS BUILDERS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MASTERS BUILDERS, INC. in 670 PROSPECT AVENUE, LAKEWOOD, NJ 08701 (NAICS 238130). OSHA activity number 342297231.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MASTERS BUILDERS, INC.
- Site address
- 670 PROSPECT AVENUE
- City
- LAKEWOOD
- State
- NJ
- ZIP
- 08701
- Mailing
- 272 DUNNS MILL ROAD SUITE 262, BORDENTOWN, NJ 08505
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 26
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 F03
- Issued
- Jul 24, 2017
- Abate by
- Aug 10, 2017
- Penalty
- Initial $9,760 · Current $9,760
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a- 670 Prospect Avenue, Lakewood NJ - Company employees were exposed to fall hazards, in excess of 23 feet to the ground surface below, while performing siding installation from a pump jack scaffold that was without bracing installed 4 feet above the brace to be passed. On the day of the worksite inspection, this scaffold was not inspected for visible defects, prior to its use, by a competent person. Condition observed on or about 05/03/17. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
- — Z (S) $9760
1926.451 F07
- Issued
- Jul 24, 2017
- Abate by
- Aug 10, 2017
- Penalty
- Initial $9,760 · Current $9,760
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration; Such activities were not performed only by experienced and trained employees selected for such work by the competent person: a- 670 Prospect Avenue, Lakewood NJ - Company employees were exposed to fall hazards, in excess of 23 feet to the ground surface below, while performing siding installation from a pump jack scaffold that was without bracing installed 4 feet above the brace to be passed, was missing end stops and was missing a screen that run the entire length of the active walking/working surface. On the day of the worksite inspection, this scaffold was not erected under the supervision and direction of a competent person. Condition noted on or about 05/03/17. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
- — Z (S) $9760
1926.451 G04 I
- Issued
- Jul 24, 2017
- Abate by
- Jul 28, 2017
- Penalty
- Initial $9,760 · Current $9,760
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms. a- Building M, 145 Cliffwood Avenue, Aberdeen NJ - Company employees were exposed to fall hazards, in excess of 23 feet to the ground surface below, while performing siding installation from a pump jack scaffold that was missing end stops and was missing a screen the length of the active walking/working surface. Condition observed on or about 04/05/17. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
- — Z (S) $9760
1926.452 J02
- Issued
- Jul 24, 2017
- Abate by
- Jul 28, 2017
- Penalty
- Initial $9,760 · Current $9,760
General-duty citation text
29 CFR 1926.452(j)(2): When the pump jack had to pass bracing already instaled,k an additional brace was not install approximately 4 feet (1.2 m) above the brace to be passed, and was not left in place until the pump jack was moved and the original brace reinstated: a- 670 Prospect Avenue, Lakewood NJ - Company employees were exposed to fall hazards, in excess of 23 feet to the ground surface below, while performing siding installation from a pump jack scaffold that was without bracing installed 4 feet above the brace to be passed. Condition observed on or about 05/03/17. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
- — Z (S) $9760
1926.454 A
- Issued
- Jul 24, 2017
- Abate by
- Aug 10, 2017
- Penalty
- Initial $6,972 · Current $6,972
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a- 670 Prospect Avenue, Lakewood NJ - Company employees were exposed to fall hazards, in excess of 23 feet to the ground surface below, while performing siding installation from a pump jack scaffold that was without bracing installed 4 feet above the brace to be passed, was missing end stops on both ends of the walking/working surface and was not supplied with a screen that ran the entire length of the scaffold's active walking/working surface. On the day of the worksite inspection, all of the worksite company employees had not received scaffold hazard recognition and minimization training by a qualified person. Condition noted on or about 05/03/17. NOTE: IN ADDITION TO ABATEMENT CERTIFICATION, THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT DOCUMENTATION FOR THIS ITEM, FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (1)
- — Z (S) $6972
More inspections at Masters Builders, INC.
View Masters Builders, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342297231.