Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: NIKLYN CORP

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of NIKLYN CORP in 400 SAKET POINT ROAD, NORTH HAVEN, CT 06473 (NAICS 332813). OSHA activity number 342297397.

Watch Niklyn Corp — free Get an email when a new federal OSHA severe-injury report for Niklyn Corp is published. One employer, no account, unsubscribe in one click.
Establishment
NIKLYN CORP
Site address
400 SAKET POINT ROAD
City
NORTH HAVEN
State
CT
ZIP
06473
Mailing
PO BOX 268, DURHAM, CT 06422
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332813
Employees
6
Ownership type
A

10 citations on file for this inspection.

1910.106 E02 II A

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2716.00 · Current $1358.00 Reduced
29 CFR 1910.106(e)(2)(ii)(a): Except as provided in subdivisions (b) and (c) of this subdivision, all storage shall comply with paragraph (d) (3) or (4) of this section.    Back room:  The large stockpile of flammable liquids were stored outside of an inside storage room or storage cabinet.
Recent events (2)
  • — I (S) $1358
  • — Z (S) $2716

1910.107 E02

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.107(e)(2): The quantity of flammable liquids or liquids with a flashpoint greater than 199.4 degrees F (93 degrees C) kept in the vicinity of spraying operations were not a minimum required for operations or they exceeded a supply for one day or one shift:   Backroom: The quantity of the flammable liquids stored within very close proximity of the spraying operation were a lot more than for the quantity that needed for one day or one shift operation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 L03

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $3803.00 · Current $1902.00 Reduced
29 CFR 1910.107(l)(3): The applicable provisions of the Standard for Ovens and Furnaces, NFPA No. 86A-1969, were not met:    Shop: The industrial oven did not meet the requirements of  NFPA No. 86A-1969, creating potential employee exposure to explosion and/or fire hazards.
Recent events (2)
  • — I (S) $1901.5
  • — Z (S) $3803

1910.132 D01

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2173.00 · Current $1087.00 Reduced
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):    Workplace: The employer did not assess the workplace to determine which necessitate and appropriate types of personal protective equipment (PPE) for employees.
Recent events (2)
  • — I (S) $1086.5
  • — Z (S) $2173

1910.132 F01

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.132(f)(1): The employer shall provide training to each employee who is required by this section to use PPE:of personal protective equipment (PPE):  Workplace: The employer did not provide training and information to the employees on the Workplace Hazard Assessment for PPE.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2716.00 · Current $1358.00 Reduced
29 CFR 1910.219(b)(1): Flywheel(s) with parts seven feet or less above floor(s) or platform(s) were not guarded in accordance with the requirements specified in 29 CFR 1910.219(b)(1)(i) through (b)(1)(iv)(a)    Shop; The flywheel located on the blower motor of the Wisconsin industrial oven was not guarded exposing employees to ingoing nip points.
Recent events (2)
  • — I (S) $1358
  • — Z (S) $2716

1910.303 B02

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $3803.00 · Current $1902.00 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    Shop:  The circuit breaker panel was not appropriately installed with proper means of securing and proper cove.
Recent events (2)
  • — I (S) $1901.5
  • — Z (S) $3803

1910.303 G02 I

Serious Gravity 10 1 instance 4 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):  Shop:  The electrical boxes, such as (but not limited to) panels, junctions boxes and breaker boxes were not appropriately covered, exposing live parts ranging from 277/ 480 volts to 110/ 220 volts.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 1 1 instance 4 exposed
Issued
Penalty
Initial $1630.00 · Current $815.00 Reduced
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):     Workplace: The employer did not develop, implement, and maintain at each workplace, a written hazard communication program where employees were required to work with chemicals.
Recent events (2)
  • — I (S) $815
  • — Z (S) $1630

1910.1200 E01 I

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(e)(1)(i): The employer did not compile a list of the hazardous chemicals known to be present using a product identifier that was referenced on the appropriate safety data sheet.  Workplace:  The employer did not develop a list of hazardous chemical that were present in the workplace.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342297397.