SAN ANTONIO, TX ·
OSHA Inspection: J CRUZ COLIN CHAVEZ
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of J CRUZ COLIN CHAVEZ in 1639 CABLE RANCH RD, SAN ANTONIO, TX 78245 (NAICS 238170). OSHA activity number 342300126.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J CRUZ COLIN CHAVEZ
- Site address
- 1639 CABLE RANCH RD
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78245
- Mailing
- 8712 KIMWOOD DR, HOUSTON, TX 77080
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 4
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1926.451 G01 VII
- Issued
- May 31, 2017
- Penalty
- Initial $2,173 · Current $1,304 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee was not protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of 29 CFR 1910.451: Building 10: On or about May 3, 2017, employees were exposed to fall hazards to the unpaved ground below when working from a pump jack scaffold without guardrails, while performing siding work on an apartment building.
Recent events (2)
- · I (S) $1303.8
- · Z (S) $2173
1926.452 J02
- Issued
- May 31, 2017
- Penalty
- Initial $2,173 · Current $1,304 Reduced
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary: Building 10, on or about May 3, 2017, employees were exposed to fall hazards to the unpaved ground below when working from a pump jack scaffold that was not secured at the bottom while performing siding work on a apartment building.
Recent events (2)
- · I (S) $1303.8
- · Z (S) $2173
1926.501 B13
- Issued
- May 31, 2017
- Penalty
- Initial $2,173 · Current $1,304 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): Building 10: On or about May 3, 2017, employees without fall protection were exposed to fall hazards greater than 6 feet to the unpaved ground below, while installing siding on an apartment building.
Recent events (2)
- · I (S) $1303.8
- · Z (S) $2173
More inspections in this industry (NAICS 238170)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342300126.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.