Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: CONSOLIDATED PIPE & SUPPLY COMPANY (ALABAMA) INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CONSOLIDATED PIPE & SUPPLY COMPANY (ALABAMA) INC. in 5200 TRANSPORT BLVD, COLUMBUS, GA 31907 (NAICS 423840). OSHA activity number 342304961.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Consolidated Pipe & Supply Company (Alabama) INC. for free Get an email when a new federal OSHA severe-injury report for Consolidated Pipe & Supply Company (Alabama) INC. is published. One employer, no account, unsubscribe in one click.
Site address
5200 TRANSPORT BLVD
City
COLUMBUS
State
GA
ZIP
31907
Mailing
1205 HILLTOP PARKWAY, BIRMINGHAM, AL 35204
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423840
Employees
9
Ownership type
Private (A)

5 citations on file for this inspection.

1910.147 C04 II B

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 13, 2017
Abate by
Aug 8, 2017
Penalty
Initial $6,157 · Current $3,694 Reduced
29 CFR 1910.147(c)(4)(ii)(B): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy.  a) Coring Machine Area: On or about May 4, 2017, and at times prior, the employer exposed employees to struck-by hazards in that no specific procedures to control hazardous electrical and hydraulic energy were developed for changing drill bits on the Core-Matic Automated Manhole Coring Machine (Model CA4N Serial Number PS-CA4N-0108-027).
Recent events (2)
  • · I (S) $3694.2
  • · Z (S) $6157

1910.157 C01

Other-than-serious 1 instance 1 exposed
Issued
Jul 13, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury.  a) South Wall, Weld Shop: On or about May 4, 2017, and at times prior, the employer exposed employees to fire hazards in that a fire extinguisher (Amerex ABC Dry Chemical Model B443) was not properly mounted.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.178 P01

Other-than-serious 1 instance 2 exposed
Issued
Jul 13, 2017
Penalty
Initial $864 · Current $518 Reduced
29 CFR 1910.178(p)(1): If at any time a powered industrial truck is found to be in need of repair, defective, or in any way unsafe, the truck shall be taken out of service until it has been restored to safe operating condition.  a) Warehouse: On or about May 04, 2017, and at times prior, the employer exposed employees to struck-by hazards by not taking Forklift (Serial Number AT19C50402) out of service, in that the forklift had a frayed hydraulic hose that control the mast lift.
Recent events (2)
  • · I (O) $518.4
  • · Z (O) $864

1910.212 A03 II

Other-than-serious 1 instance 1 exposed
Issued
Jul 13, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.  a) Custom Utility Concrete Vault Fabrication: 5200 Transport Blvd Columbus, GA 31907. On or about May 4, 2017, and at times prior, the employer exposed employees to struck-by hazards when cutting metal pipes with an abrasive cutting machine (DeWalt Model DW871 Serial number 486412) that had an inoperative guard.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.253 B02 II

Other-than-serious 1 instance 1 exposed
Issued
Jul 13, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders shall be stored in a well-protected, well-ventilated, dry location, at least 20 (6.1 m) feet from highly combustible materials such as oil or excelsior. Cylinders should be stored in definitely assigned places away from elevators, stairs, or gangways. Assigned storage spaces shall be located where cylinders will not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons. Cylinders shall not be kept in unventilated enclosures such as lockers and cupboards.  a) East Wall, Weld Shop: On or about May 4, 2017, and at times prior, the employer exposed employees to struck-by hazards, in that an Argon cylinder was not properly secured.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342304961.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.