Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: FIBERCORR MILLS, LLC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of FIBERCORR MILLS, LLC. in 670 17TH ST. N.W., MASSILLON, OH 44646 (NAICS 322299). OSHA activity number 342319100.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fibercorr Mills, LLC. for free Get an email when a new federal OSHA severe-injury report for Fibercorr Mills, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
670 17TH ST. N.W.
City
MASSILLON
State
OH
ZIP
44646
Mailing
670 17TH ST. N.W., MASSILLON, OH 44646
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322299
Employees
87
Ownership type
A

2 citations on file for this inspection.

1910.147 D

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 14, 2017
Abate by
Jul 11, 2017
Penalty
Initial $8,873 · Current $6,211 Reduced
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):    On or about 5/12/2017, the employees tasked with wiping off debris from the cleaning blades, did not conduct the following procedures to control hazardous energy as required by 29 CFR 1910.147(d)(1)-(6):    1) The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment,     2) All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s),    3) A lockout device was not attached to all power sources,    4) Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware shall be provided by the employer for isolating, securing or blocking of machines or equipment from energy sources,    5) Prior to starting work on machines or equipment that had been locked out or tagged out, the authorized employee did not verify that isolation and deenergization of the machine or equipment had been accomplished.
Recent events (2)
  • · I (S) $6211.1
  • · Z (S) $8873

1910.212 A01

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 14, 2017
Abate by
Aug 30, 2017
Penalty
Initial $8,873 · Current $0 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    On or about 5/12/2017, the employer failed to ensure that the dryer rollers were effectively guarded. No guarding was installed.
Recent events (2)
  • · I (S) $0
  • · Z (S) $8873

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342319100.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.