OSHA Inspection: JEPOL CONSTRUCTION INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JEPOL CONSTRUCTION INC. in 80 WHITE STREET, NEW YORK, NY 10013 (NAICS 236116). OSHA activity number 342327939.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Jepol Construction INC. — free Get an email when a new federal OSHA severe-injury report for Jepol Construction INC. is published. One employer, no account, unsubscribe in one click.
Site address
80 WHITE STREET
City
NEW YORK
State
NY
ZIP
10013
Mailing
49-01 GRAND AVENUE, MASPETH, NY 11378
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236116
Employees
20
Ownership type
A

10 citations on file for this inspection.

1926.405 A02 II E

Serious Gravity 1 1 instance 6 exposed
Issued
Oct 2, 2017
Abate by
Oct 13, 2017
Penalty
Initial $4,183 · Current $3,250 Reduced
29 CFR 1926.405(a)(2)(ii)(E): Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage:    a) On or about 5/9/2017, At the jobsite:  Not all light bulbs in stairway B were provided with guards.      Abatement certification is required for these items.
Recent events (3)
  • — F (S) $3250
  • — C (S) $4183
  • — Z (S) $4183

1926.451 E01

Serious Gravity 5 2 instances 4 exposed
Issued
Oct 2, 2017
Abate by
Oct 13, 2017
Penalty
Initial $6,972 · Current $5,250 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used:    a) On or about 5/9/2017, At the jobsite:  Employees were accessing and egressing a rolling scaffold located on the second floor by climbing the end rails which had spacing of two feet.  Employees exposed to falls of eight feet.      b) On or about 5/9/2017, At the jobsite:  Employees were accessing and egressing a fabricated frame scaffold located in stairwell B.  The employees were climbing the sides and cross bracing.  Employees exposed to falls of 42 feet.     Abatement certification is required for this item.
Recent events (3)
  • — F (S) $5250
  • — C (S) $6972
  • — Z (S) $6972

1926.501 B15

Serious Gravity 5 2 instances 5 exposed
Issued
Oct 2, 2017
Abate by
Oct 13, 2017
Penalty
Initial $6,972 · Current $3,250 Reduced
29 CFR 1926.501(b)(15): Each employee on a walking/working surface 6 feet (1.8 meters) or more above lower levels was not protected from falling by a guardrail system, safety net system, or personal fall arrest system:    a) On or about 5/9/2017, At the jobsite:  Employees were walking on the top of floor joists and in spots plywood, exposed to falls of over 42 feet.        b) On or about 5/9/2017, At the jobsite:  Employees were walking and working near an open roof hatch, exposed to falls of 14 feet.      Abatement certification is required for this item.
Recent events (3)
  • — F (S) $3250
  • — C (S) $6972
  • — Z (S) $6972

1926.552 C08

Serious Gravity 1 1 instance 20 exposed
Issued
Oct 2, 2017
Abate by
Oct 13, 2017
Penalty
Initial $4,183 · Current $5,250
29 CFR 1926.552(c)(8): Personnel hoist doors or gates were not provided with electrical contacts which do not allow movement of the hoist when door or gate was open:    a) On or about 5/9/2017, At the jobsite:  The building elevator was operated with its interior door opened as the door interlock system had been made inoperable.     Abatement certification is required for this item.
Recent events (3)
  • — F (S) $5250
  • — C (S) $4183
  • — Z (S) $4183

1926.404 B01 I

Serious Gravity 5 3 instances 3 exposed
Issued
Oct 2, 2017
Abate by
Oct 13, 2017
Penalty
Initial $6,972 · Current $5,250 Reduced
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites:    a) On or about 5/9/2017, At the jobsite:  Employees were utilizing an electric wet saw to cut masonry block on an upper floor, there was no ground fault circuit interrupter or assured grounding conductor program in use.      b) On or about 5/9/2017, At the jobsite:  Employees were utilizing an electric cement mixer on a middle floor, there was no ground fault circuit interrupter or assured grounding conductor program in use.      c) On or about 5/9/2017, At the jobsite:  Employees were utilizing a hand held electric blower on the roof, there was no ground fault circuit interrupter or assured grounding conductor program in use.     Abatement certification is required for these items.
Recent events (3)
  • — F (S) $5250
  • — C (S) $6972
  • — Z (S) $6972

1926.404 F06

Serious Gravity 5 3 instances 3 exposed
Issued
Oct 2, 2017
Abate by
Oct 13, 2017
Penalty
Initial $6,972 · Current $0 Reduced
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:    a) On or about 5/9/2017, At the jobsite:  Employees were utilizing an electric wet saw to cut masonry block, that was not provided with a continuous path to ground.      b) On or about 5/9/2017, At the jobsite:  Employees were utilizing an electric cement mixer on a stairway landing, that was not provided with a continuous path to ground.      c) On or about 5/9/2017, At the jobsite:  Employees were utilizing a hand held electric blower on the roof, that was not provided with a continuous path to ground.     Abatement certification is required for these items.
Recent events (3)
  • — F (S) $0
  • — C (S) $6972
  • — Z (S) $6972

1926.1052 C01 II

Serious Gravity 5 3 instances 6 exposed
Issued
Oct 2, 2017
Abate by
Oct 13, 2017
Penalty
Initial $6,972 · Current $5,250 Reduced
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a stairrail system along each unprotected side or edge:    a) On or about 5/9/2017, At the jobsite:  Stairway B had no hand rail system between the first and second floor.  Employees exposed to falls of up to 16 feet.     b) On or about 5/9/2017, At the jobsite:  Stairway A had no midrail between the third and fourth floor and along the third floor opening.  Employees exposed to falls of up to 14 feet.     Abatement certification is required for this item.
Recent events (3)
  • — F (S) $5250
  • — C (S) $6972
  • — Z (S) $6972

1926.1052 C12

Serious Gravity 5 2 instances 6 exposed
Issued
Oct 2, 2017
Abate by
Oct 13, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.1052(c)(12): Unprotected sides and edges of stairway landings were not provided with guardrail systems that meet the criteria contained in Subpart M of 29 CFR 1926:    a) On or about 5/9/2017, At the jobsite:  Stairway B had no guard rail system on the landings between the first and second floor and the second and third floor.  Employees exposed to falls of up to 16 feet.     Abatement certification is required for this item.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.1053 A24

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 2, 2017
Abate by
Oct 13, 2017
Penalty
Initial $5,577 · Current $0 Reduced
29 CFR 1926.1053(a)(24): The side rails of through or sidestep fixed ladders did not extend 42 inches (1.1 m) above the top of the access level or landing platform served by the ladder:    a) On or about 5/9/2017, At the jobsite:  The fixed metal ladder servicing the roof hatch was not provided with a grab bar above the roof level.     Abatement certification is required for this item.
Recent events (3)
  • — F (S) $0
  • — C (S) $5577
  • — Z (S) $5577

1926.403 B01 I

Other-than-serious 1 instance 2 exposed
Issued
Oct 2, 2017
Abate by
Oct 13, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.403(b)(1)(i): Safety of equipment was not determined on the basis of suitability of the equipment for an identified purpose as evidenced by listing, labeling, or certification for that identified purpose:  a) On or about 5/9/2017, At the jobsite:  A relocatable power tap was mounted to the side of a wet saw and being used as an appliance switch.    Abatement certification is required for this item.