Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ROOF CO NA INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ROOF CO NA INC in 10901 JAYNES PLAZA, OMAHA, NE 68164 (NAICS 238160). OSHA activity number 342329828.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Roof CO NA INC — free Get an email when a new federal OSHA severe-injury report for Roof CO NA INC is published. One employer, no account, unsubscribe in one click.
Establishment
ROOF CO NA INC
Site address
10901 JAYNES PLAZA
City
OMAHA
State
NE
ZIP
68164
Mailing
5565 QUAM AVE NE, SAINT MICHAEL, MN 55376
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
10
Ownership type
A

2 citations on file for this inspection.

1926.501 B11

Serious Gravity 10 1 instance 7 exposed
Issued
Sep 26, 2017
Abate by
Oct 23, 2017
Penalty
Initial $3,803 · Current $2,500 Reduced
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems:    The controlling contractor is failing to ensure that all employees of the sub-contractor Casiqu Enterprises, Inc exposed to fall hazards while working on a commercial roof are utilizing fall protection.  This most recently occurred on May 16, 2017 on the jobsite located at 10901 Jaynes Plaza, Omaha, NE 68164.  Employees of the controlling contractor were in a position to personally observe the sub-contract employees on the roof of a 3-story apartment with a 6 in 12 steep sloped roof at heights greater than 6 feet above the ground and not utilizing any form of fall protection.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $3803

1926.502 D21

Serious Gravity 10 1 instance 7 exposed
Issued
Sep 26, 2017
Abate by
Oct 23, 2017
Penalty
Initial $3,803 · Current $2,500 Reduced
29 CFR 1926.502(d)(21): Personal fall arrest systems were not inspected prior to each use for wear, damage, and other deterioration, and/or defective components were not removed from service:     The general contractor is exposing employees from the sub-contractor Casiqu Enterprises, Inc to fall hazards associated with using faulty personal fall arrest systems (PFAS) while working on a commercial roof.  This most recently occurred on May 16, 2017 on the jobsite located at 10901 Jaynes Plaza, Omaha, NE 68164.  Sub-contract employees are working on a roof that has a 6 in 12 steep sloped pitch and a ground to eave height of about 30 feet.  The general contractor is providing the sub-contractor employees with PFAS that has not been inspected.  The PFAS has connectors that are rusted which can cause them to break easily or cause cuts and tears to other components of the PFAS.  There are also frayed ropes which can cause the PFAS to not function properly in the event of a fall.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $3803

View Roof CO NA INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342329828.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.