Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: KCS INTERNATIONAL INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of KCS INTERNATIONAL INC. in 205 CHARLES ST., OCONTO, WI 54153 (NAICS 336612). OSHA activity number 342332046.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch KCS International INC. for free Get an email when a new federal OSHA severe-injury report for KCS International INC. is published. One employer, no account, unsubscribe in one click.
Site address
205 CHARLES ST.
City
OCONTO
State
WI
ZIP
54153
Mailing
804 PECOR ST, OCONTO, WI 54153
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336612
Employees
40
Ownership type
Private (A)

2 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 2, 2017
Penalty
Initial $11,408 · Current $5,704 Reduced
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.    On or about May 9, 2017, an employee was exposed to the point of operation of an Edwards 1/4" Truecut Model 6-5/3000 metal sheer as the finger guard did not prevent the operator from accessing the danger zone during the operating cycle.
Recent events (2)
  • · I (S) $5704
  • · Z (S) $11408

1910.303 B02

Other-than-serious 1 instance 3 exposed
Issued
Jun 2, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.  A metallic outlet box (handy box) was not installed in accordance with the UL identifier QCIT which states the box shall be mounted in or on a surface.  The handy box was attached to a flexible cord to be used as a switch for a fluorescent light above the Edwards 1/4" Truecut Model 6-5/3000 metal sheer.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View KCS International INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342332046.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.