FRIENDSWOOD, TX —
OSHA Inspection: ABLE & WILLING CONSTRUCTION, INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of ABLE & WILLING CONSTRUCTION, INC. in 18840 GULF FREEWAY, FRIENDSWOOD, TX 77546 (NAICS 238140). OSHA activity number 342337359.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ABLE & WILLING CONSTRUCTION, INC.
- Site address
- 18840 GULF FREEWAY
- City
- FRIENDSWOOD
- State
- TX
- ZIP
- 77546
- Mailing
- 13721 ALMEDA SCHOOL ROAD, HOUSTON, TX 77047
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 15
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 B01
- Issued
- Jul 10, 2017
- Abate by
- Jul 14, 2017
- Penalty
- Initial $5,070 · Current $3,042 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): a) At the site, on the south side patio canopy, a fabricated framed scaffold was not fully planked on the working level.
Recent events (2)
- — I (S) $3042
- — Z (S) $5070
1926.451 E01
- Issued
- Jul 10, 2017
- Abate by
- Jul 14, 2017
- Penalty
- Initial $5,070 · Current $3,042 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used: a) At the site, on the south patio canopy area, a fabricated frame scaffold was not equipped with a safe means of access or egress. b) At the site, on the east exterior area, a fabricated frame scaffold was not equipped with a safe means of access or egress.
Recent events (2)
- — I (S) $3042
- — Z (S) $5070
1926.451 F03
- Issued
- Jul 10, 2017
- Abate by
- Jul 24, 2017
- Penalty
- Initial $5,070 · Current $0 Reduced
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a) At the work site, a fabricated frame scaffold was not inspected by a competent person in that the designated competent person did not know that working levels of scaffold must be fully planked between uprights; that a safe means of access and egress must be provided; and that guardrails must be complete.
Recent events (2)
- — I (S) $0
- — Z (S) $5070
1926.451 G01 VII
- Issued
- Jul 10, 2017
- Abate by
- Jul 14, 2017
- Penalty
- Initial $3,622 · Current $2,174 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section: a) At the site, on the south patio canopy, employees performing bricklaying were exposed to fall hazards while working from a fabricated frame scaffold, set on incline, 18' above a lower level.
Recent events (2)
- — I (S) $2174
- — Z (S) $3622
1926.501 B10
- Issued
- Jul 10, 2017
- Abate by
- Jul 14, 2017
- Penalty
- Initial $3,622 · Current $0 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels, was not protected from falling by guardrail systems, safety net systems, or personal fall arrest system: a) At the site, on the south patio canopy, a laborer was exposed to fall hazards of 10' while performing housekeeping without fall protection.
Recent events (2)
- — I (S) $0
- — Z (S) $3622
More inspections at Able & Willing Construction, INC.
View Able & Willing Construction, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238140)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342337359.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.