PHILADELPHIA, PA —
OSHA Inspection: DELAWARE VALLEY CUTTING SERVICES, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of DELAWARE VALLEY CUTTING SERVICES, INC. in 2400 MARKET STREET, PHILADELPHIA, PA 19103 (NAICS 238990). OSHA activity number 342337714.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DELAWARE VALLEY CUTTING SERVICES, INC.
- Site address
- 2400 MARKET STREET
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19103
- Mailing
- 101 WASHINGTON AVENUE, GLOUCESTER CITY, NJ 08030
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238990
- Employees
- 7
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.134 E01
- Issued
- Nov 2, 2017
- Abate by
- Nov 22, 2017
- Penalty
- Initial $5,387 · Current $5,387
9010
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a. 2400 to 2402 Market Street, Philadelphia, PA 19103 - The employer did not provide medical evaluation for an employee who was using an air-purifying MSA Advantage 200 LS half-mask respirator equipped with P100 Cartridges. While using a hand-held Husqvarna K970 (Max 4300 RPM) power saw to cut concrete. Observed On 06/16/17
Recent events (2)
- — I (O) $5387
- — Z (S) $5387
1910.134 F02
- Issued
- Nov 2, 2017
- Abate by
- Nov 22, 2017
- Penalty
- Initial $5,387 · Current $0 Reduced
9010
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: (Construction Reference 1926.103) a. 2400 to 2402 Market Street, Philadelphia, PA 19103 - The employer did not ensure that an employee using air-purifying MSA Advantage 200 LS half-mask respirator equipped with P100 Cartridges was fit tested prior to initial use of the respirator. While using a hand-held Husqvarna K970 (Max 4300 RPM) power saw to cut concrete. Observed On 06/16/17
Recent events (2)
- — I (S) $0
- — Z (S) $5387
More inspections at Delaware Valley Cutting Services, INC.
View Delaware Valley Cutting Services, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238990)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342337714.