Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GARCIA STUCCO

Special Programs inspection · Safety discipline

On , OSHA opened a special Programs safety inspection of GARCIA STUCCO in 2103 ARGONNE UNIT A, HOUSTON, TX 77019 (NAICS 238140). OSHA activity number 342339041.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Garcia Stucco — free Get an email when a new federal OSHA severe-injury report for Garcia Stucco is published. One employer, no account, unsubscribe in one click.
Establishment
GARCIA STUCCO
Site address
2103 ARGONNE UNIT A
City
HOUSTON
State
TX
ZIP
77019
Mailing
5754 MEADOW CREEK LANE, HOUSTON, TX 77077
Inspection type
Special Programs (K)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
5
Ownership type
A

2 citations on file for this inspection.

1926.451 C01 II

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 9, 2017
Abate by
Jun 28, 2017
Penalty
Initial $3,803 · Current $1,901 Reduced
29 CFR 1926.451(c)(1)(ii): Guys, ties, and/or braces were not installed according to the scaffold manufacturer's recommendations or at the closest horizontal member to the 4:1 height and repeated vertically at locations of horizontal members every 20 feet (56.1 m) or less thereafter for scaffolds 3 feet (0.91 m) wide or less, and every 26 feet (7.9 m) or less thereafter for scaffolds greater than 3 feet (0.91m) wide:    a)  At 2103 Argonne, Houston Texas, tubular welded frame scaffolding, approximately 42 feet high, was not secured to the structure, exposing employees to fall hazards. 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access:     a)  At 2103 Argonne, Houston, Texas, employees used crossbraces to access a tubular welded frame scaffold, exposing employees to fall hazards.
Recent events (2)
  • — I (S) $1901
  • — Z (S) $3803

1926.451 G01 VII

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 9, 2017
Abate by
Jun 28, 2017
Penalty
Initial $3,803 · Current $3,803
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section:  a)  At 2103 Argonne, Houston, Texas, employees working from tubular welded frame scaffolding, approximately 42 feet above the ground, were not protected from falling by any type of a fall protection system.
Recent events (2)
  • — I (S) $3803
  • — Z (S) $3803

View Garcia Stucco's full OSHA safety record →