HOUSTON, TX ·
OSHA Inspection: D-L FLANGE CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of D-L FLANGE CORPORATION in 7785 E. LITTLE YORK RD., HOUSTON, TX 77016 (NAICS 332919). OSHA activity number 342347291.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- D-L FLANGE CORPORATION
- Site address
- 7785 E. LITTLE YORK RD.
- City
- HOUSTON
- State
- TX
- ZIP
- 77016
- Mailing
- 7785 E. LITTLE YORK RD., HOUSTON, TX 77016
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332919
- Employees
- 20
- Ownership type
- Private (A)
Citations
7 citations on file for this inspection.
1910.178 L01 I
- Issued
- Sep 25, 2017
- Abate by
- Oct 19, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): On or about May 23, 2017 at the facility where employees in the facility were required to operate forklifts without having been trained and evaluated.
Recent events (1)
- · Z (O) $0
1910.178 P01
- Issued
- Sep 25, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s) On or about May 23, 2017 throughout the facility where employees were exposed to struck-by hazards while operating Toyota forklifts, SN: 60081, 68183, 63986 and 69361 that were observed to have brake lights, headlights and turn signals that did not work.
Recent events (1)
- · Z (O) $0
1910.184 I01
- Issued
- Sep 25, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.184(i)(1): Synthetic web sling(s) were not marked or coded to show rated capacities for each type of hitch and type of synthetic web material: On or about May 23, 2017 at the facility where employees were exposed to struck-by hazards when using a Hunter synthetic (nylon) web sling SN: 95662-1-1 which had the label torn at the bottom which did not show the rated capacities.
Recent events (1)
- · Z (O) $0
1910.212 A01
- Issued
- Sep 25, 2017
- Abate by
- Sep 29, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: On or about May 23, 2017 at the facility where employees were exposed to a caught-in or between hazard while operating a Bullard vertical cutmaster lathe without proper guarding of rotating parts.
Recent events (1)
- · Z (O) $0
1910.219 C03
- Issued
- Sep 25, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(c)(3): Vertical or inclined shafting seven -7 feet or less from floor or working platform was not enclosed with stationary casing(s) On or about May 23, 2017 at the facility where employees were exposed to a struck-by and caught in between hazards when working at Bullard vertical cutmaster machines without guarding the exposed vertical shafting.
Recent events (1)
- · Z (O) $0
1910.242 B
- Issued
- Sep 25, 2017
- Abate by
- Oct 10, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: On or about May 23, 2017 throughout the facility where employees were exposed to injection hazards while blowing off equipment without reducing the air pressure below 30 p.s.i.
Recent events (1)
- · Z (O) $0
1910.305 B01 II
- Issued
- Sep 25, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: On or about May 23, 2017 at the facility where employees were exposed to electrical hazards when using electrical boxes that had unused openings.
Recent events (1)
- · Z (O) $0
More inspections in this industry (NAICS 332919)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342347291.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.