Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: AKTOR CORPORATION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AKTOR CORPORATION in 2330 WATT ST., SCHENECTADY, NY 12304 (NAICS 238160). OSHA activity number 342348091.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Aktor Corporation for free Get an email when a new federal OSHA severe-injury report for Aktor Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
AKTOR CORPORATION
Site address
2330 WATT ST.
City
SCHENECTADY
State
NY
ZIP
12304
Mailing
44 TIVOLI STREET, ALBANY, NY 12204
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
Private (A)

5 citations on file for this inspection.

1926.102 A02

Serious Gravity 1 1 instance 1 exposed
Issued
May 30, 2017
Penalty
Initial $3,232 · Current $2,424 Reduced
29 CFR 1926.102(a)(2): 29 CFR 1926.102(a)(2): Eye and face protection equipment did not meet the requirements of ANSI Z87.1-1968, Practice for Occupational and Educational Eye and Face Protection:      (a) At the worksite, during sheet metal work:  Employee was wearing ordinary sunglasses while operating a Makita 4.5" angle grinder which was equipped with a cut-off wheel.
Recent events (2)
  • · I (S) $2424
  • · Z (S) $3232

1926.303 B01

Serious Gravity 1 1 instance 1 exposed
Issued
May 30, 2017
Penalty
Initial $3,802 · Current $2,852 Reduced
29 CFR 1926.303(b)(1): Grinding machines were not equipped with safety guards in conformance with the requirements of ANSI B7.1-1970, Safety Code for the Use, Care, and Protection of abrasive wheels, and paragraph (d) of this section.  (a) At the jobsite, during sheetmetal work:  Makita 4.5" angle grinder was used with cut-off wheel; the grinder did not have a safety guard installed.
Recent events (2)
  • · I (S) $2851.5
  • · Z (S) $3802

1926.150 C01 I

Other-than-serious 1 instance 1 exposed
Issued
May 30, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.150(c)(1)(iv): A fire extinguisher, rated not less than 10B, was not provided within 50 feet of wherever more than 5 gallons of flammable or combustible liquids or 5 pounds of flammable gas are being used on the jobsite.  (a) Roof of building, during roofing work:  On or prior to 5/24/17, no portable fire extinguisher(s) were available on the roof of the building, where employees were using 5 a gallon container of JM EPDM Splice Cleaner, a flammable liquid.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1926.602 D

Other-than-serious 1 instance 3 exposed
Issued
May 30, 2017
Abate by
Jun 19, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.602(d): The employer did not certify that each operator had been trained and evaluated as required by paragraph 29 CFR 1910.178(l):  Note: The requirements applicable to construction work under paragraph (d) of this section are identical to those set forth at paragraph (l) of 29 CFR 1910.178.    (a) At the jobsite, during roofing work:  On or prior to 5/24/17, the operator of an Ingersoll Rand telehandler had not been recertified within 3 years.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1926.1053 B16

Other-than-serious 1 instance 2 exposed
Issued
May 30, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired.  (a) At the jobsite, during roofing work:   A Michigan fiberglass extension ladder was in use with structural damage to one end, including broken/missing rungs and cracked fiberglass rails; ladder was used for roof access at the north side (back) of  the building.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Aktor Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342348091.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.