Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: R.B. WOODCRAFT, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of R.B. WOODCRAFT, INC. in 1860 ERIE BLVD EAST, SYRACUSE, NY 13210 (NAICS 337212). OSHA activity number 342348380.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch R.B. Woodcraft, INC. — free Get an email when a new federal OSHA severe-injury report for R.B. Woodcraft, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1860 ERIE BLVD EAST
City
SYRACUSE
State
NY
ZIP
13210
Mailing
1860 ERIE BLVD EAST, SYRACUSE, NY 13210
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337212
Employees
50
Ownership type
A

5 citations on file for this inspection.

1910.147 C06 I

Serious Gravity 5 1 instance 3 exposed
Issued
Sep 15, 2017
Abate by
Oct 5, 2017
Penalty
Initial $5,387 · Current $3,232 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed:   a)  Throughout the facility, on or about 5/24/17: No periodic inspections were conducted of the energy control procedures to ensure that the procedures and requirements of the standard were being followed. Employees perform servicing and/or maintenance on various machinery or equipment including but not limited to: Holzma Edgebander; Holzma Besonsaw; Weeke Drill; Doweler Inserter; Buffering Sander and Chicago Pneumatic Compressor No. 1.
Recent events (2)
  • — I (S) $3232.2
  • — Z (S) $5387

1910.157 G02

Serious Gravity 1 1 instance 4 exposed
Issued
Sep 15, 2017
Penalty
Initial $3,232 · Current $1,939 Reduced
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter:  a)Throughout the facility, on or about 5/24/17: Training was not provided annually to employees on the use of fire extinguishers and the hazards involved with incipient stage fire fighting. Last training conducted was 3/19/2013.     * ABATEMENT NOTE: By this date the employer must either correct the alleged violation or implement a Fire Safety Policy; as outlined in 29 CFR 1910.38(a) and .39 which includes the evacuation requirements of 29 CFR 1910.157(b).
Recent events (2)
  • — I (S) $1939.2
  • — Z (S) $3232

1910.134 F02

Other-than-serious 1 instance 3 exposed
Issued
Sep 15, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2): Employer did not ensure that an employee using a tight fitting facepiece respirator was fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) was used, and at least annually thereafter:    a) Finishing Area, on or about 5/24/17: Employees required to wear half face air purifying respirators had not been fit tested annually, last fit test was conducted on 1/5/15.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.304 G05

Other-than-serious 1 instance 5 exposed
Issued
Sep 15, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous and effective:   a) Shipping Area, or about 5/24/17: Shipping wall fan had ground pin missing from plug end.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.307 C02 I

Other-than-serious 1 instance 1 exposed
Issued
Sep 15, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.307(c)(2)(i): Equipment shall be approved not only for the class of location, but also for the ignitable or combustible properties of the specific gas, vapor, dust, or fiber that will be present:   a) Custom Areal, on or about 5/24/17: Nilfisk CFM Vacuum was being used to clean up combustible Class II explosive dust and was specifically marked not to be used for flammable, combustible or explosive materials.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View R.B. Woodcraft, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342348380.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.