SYRACUSE, NY —
OSHA Inspection: R.B. WOODCRAFT, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of R.B. WOODCRAFT, INC. in 1860 ERIE BLVD EAST, SYRACUSE, NY 13210 (NAICS 337212). OSHA activity number 342348380.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- R.B. WOODCRAFT, INC.
- Site address
- 1860 ERIE BLVD EAST
- City
- SYRACUSE
- State
- NY
- ZIP
- 13210
- Mailing
- 1860 ERIE BLVD EAST, SYRACUSE, NY 13210
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337212
- Employees
- 50
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C06 I
- Issued
- Sep 15, 2017
- Abate by
- Oct 5, 2017
- Penalty
- Initial $5,387 · Current $3,232 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed: a) Throughout the facility, on or about 5/24/17: No periodic inspections were conducted of the energy control procedures to ensure that the procedures and requirements of the standard were being followed. Employees perform servicing and/or maintenance on various machinery or equipment including but not limited to: Holzma Edgebander; Holzma Besonsaw; Weeke Drill; Doweler Inserter; Buffering Sander and Chicago Pneumatic Compressor No. 1.
Recent events (2)
- — I (S) $3232.2
- — Z (S) $5387
1910.157 G02
- Issued
- Sep 15, 2017
- Penalty
- Initial $3,232 · Current $1,939 Reduced
General-duty citation text
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: a)Throughout the facility, on or about 5/24/17: Training was not provided annually to employees on the use of fire extinguishers and the hazards involved with incipient stage fire fighting. Last training conducted was 3/19/2013. * ABATEMENT NOTE: By this date the employer must either correct the alleged violation or implement a Fire Safety Policy; as outlined in 29 CFR 1910.38(a) and .39 which includes the evacuation requirements of 29 CFR 1910.157(b).
Recent events (2)
- — I (S) $1939.2
- — Z (S) $3232
1910.134 F02
- Issued
- Sep 15, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(2): Employer did not ensure that an employee using a tight fitting facepiece respirator was fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) was used, and at least annually thereafter: a) Finishing Area, on or about 5/24/17: Employees required to wear half face air purifying respirators had not been fit tested annually, last fit test was conducted on 1/5/15.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.304 G05
- Issued
- Sep 15, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous and effective: a) Shipping Area, or about 5/24/17: Shipping wall fan had ground pin missing from plug end.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.307 C02 I
- Issued
- Sep 15, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.307(c)(2)(i): Equipment shall be approved not only for the class of location, but also for the ignitable or combustible properties of the specific gas, vapor, dust, or fiber that will be present: a) Custom Areal, on or about 5/24/17: Nilfisk CFM Vacuum was being used to clean up combustible Class II explosive dust and was specifically marked not to be used for flammable, combustible or explosive materials.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at R.B. Woodcraft, INC.
View R.B. Woodcraft, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 337212)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342348380.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.