Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MARK STANLEY MASONRY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MARK STANLEY MASONRY, INC. in 2015 WOODLAWN RD., NORTHBROOK, IL 60065 (NAICS 238140). OSHA activity number 342348760.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Mark Stanley Masonry, INC. — free Get an email when a new federal OSHA severe-injury report for Mark Stanley Masonry, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2015 WOODLAWN RD.
City
NORTHBROOK
State
IL
ZIP
60065
Mailing
32867 N. ATKINSON, GRAYSLAKE, IL 60030
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
4
Ownership type
A

6 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 21, 2017
Penalty
Initial $2,716 · Current $1,480 Reduced
29 CFR 1926.100(a):  Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns:    a)  On May 24, 2017, employees engaged in hoisting operations exposed to struck-by hazards were not wearing hard hats.
Recent events (2)
  • — I (S) $1480
  • — Z (S) $2716

1926.451 B01

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 21, 2017
Abate by
Jun 27, 2017
Penalty
Initial $3,803 · Current $2,070 Reduced
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds were not fully planked or decked between the front uprights and the guardrail supports:      a) On May 24, 2017, employees were exposed to the hazard of falling up to approximately 23 feet from tubular welded frame scaffold platforms which were not fully planked.
Recent events (2)
  • — I (S) $2070
  • — Z (S) $3803

1926.451 G01

Serious Gravity 10 1 instance 3 exposed
Issued
Jun 21, 2017
Abate by
Jun 27, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level.    a)  On May 24, 2017, employees were exposed to the hazard of falling while performing masonry work from tubular welded frame scaffold platform elevated approximately 23 feet above the ground.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 C01

Other-than-serious 1 instance 3 exposed
Issued
Jun 21, 2017
Abate by
Jun 27, 2017
Penalty
Initial $3,803 · Current $500 Reduced
29 CFR 1926.451(c)(1):  Supported scaffold(s) with a height to base width (including outrigger supports) ratio greater than four to one (4:1) was not restrained from tipping by guying, tying, bracing, or equivalent means:      a)  On May 24, 2017, employees were exposed to fall hazards of approximately 23 feet while working on a frame scaffold which was not restrained from tipping by any means.
Recent events (2)
  • — I (O) $500
  • — Z (S) $3803

1926.451 E01

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 21, 2017
Abate by
Jun 27, 2017
Penalty
Initial $2,716 · Current $1,480 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.       a)  On May 24, 2017, employees working from tubular welded frame scaffolding were not provided with safe access to the work platforms of the scaffolding.
Recent events (2)
  • — I (S) $1480
  • — Z (S) $2716

1926.451 F06

Serious Gravity 5 1 instance 3 exposed
Issued
Jun 21, 2017
Abate by
Jun 27, 2017
Penalty
Initial $2,716 · Current $1,470 Reduced
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).       a) On May 24, 2017 the employer permitted employees to erect and use tubular welded framed scaffolding approximately eight feet away from a main power distribution line that was greater than 300v.
Recent events (2)
  • — I (S) $1470
  • — Z (S) $2716

View Mark Stanley Masonry, INC.'s full OSHA safety record →