Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,195,903Inspections Most recent open 2026-08-18 Last loaded 2026-08-21

OSHA Inspection: FABRIK INDUSTRIES, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of FABRIK INDUSTRIES, INC. in 5213 PRIME PARKWAY, MCHENRY, IL 60050 (NAICS 326199). OSHA activity number 342349412.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fabrik Industries, INC. for free Get an email when a new federal OSHA severe-injury report for Fabrik Industries, INC. is published. One employer, no account, unsubscribe in one click.
Site address
5213 PRIME PARKWAY
City
MCHENRY
State
IL
ZIP
60050
Mailing
5213 PRIME PARKWAY, MCHENRY, IL 60050
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
250
Ownership type
Private (A)

6 citations on file for this inspection.

1910.332 B01

Serious Gravity 10 1 instance 6 exposed
Issued
Sep 6, 2017
Abate by
Nov 13, 2017
Penalty
Initial $11,408 · Current $9,000 Reduced
29 CFR 1910.332(b)(1):  Employees shall be trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertain to their respective job assignments:     Entire Facility - On or about May 24, 2017, maintenance employees performed troubleshooting and servicing tasks on electrical components, including voltage testing on energized components in panels and bus boxes.  Employees were not trained in and familiar with safety-related work practices such as the use of special precautionary techniques, personal protective equipment (PPE), insulated tools and insulating and shielding materials necessary to safely accomplish such tasks.  Employees were exposed to the hazards of electrocution and arc flash/blast injuries.       Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
  • · I (S) $9000
  • · Z (S) $11408

1910.333 C02

Serious Gravity 10 1 instance 6 exposed
Issued
Sep 6, 2017
Abate by
Nov 13, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.333(c)(2): Only qualified persons may work on electric circuit parts or equipment that have not been deenergized under the procedures of paragraph (b) of this section. Such persons shall be capable of working safely on energized circuits and shall be familiar with the proper use of special precautionary techniques, personal protective equipment, insulating and shielding materials, and insulated tools:    Entire Facility - On or about May 24, 2017 maintenance employees performed troubleshooting and servicing tasks on energized electrical components, including voltage testing on energized components in panels and bus boxes.  The employer did not ensure that employees were qualified persons, capable of working safely through familiarity with special precautionary techniques, personal protective equipment, insulating and shielding materials and insulated tools necessary to safely accomplish such tasks. Employees were exposed to the hazards of electrocution and arc flash/blast injuries.     Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.334 C01

Serious Gravity 10 1 instance 6 exposed
Issued
Sep 6, 2017
Abate by
Nov 13, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.334(c)(1): Only qualified persons may perform testing work on electric circuits or equipment:     Entire Facility - On or about May 24, 2017 maintenance employees who were not qualified persons were assigned and permitted to perform voltage testing on energized components.    Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.333 B02 I

Serious Gravity 5 1 instance 6 exposed
Issued
Sep 6, 2017
Abate by
Nov 13, 2017
Penalty
Initial $8,149 · Current $2,000 Reduced
29 CFR 1910.333(b)(2)(i): The employer shall maintain a written copy of the procedures outlined in paragraph (b)(2) and shall make it available for inspection by employees and by the Assistant Secretary of Labor and his or her authorized representatives:     Entire Facility - On or about May 24, 2017, the employer did not maintain a written copy of procedures for locking and tagging and verification of deenergized parts of fixed electric equipment or circuits by a qualified person.  Employees were exposed to electrical shock and burn hazards.    Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
  • · I (S) $2000
  • · Z (S) $8149

1910.335 A01 I

Serious Gravity 10 1 instance 2 exposed
Issued
Sep 6, 2017
Abate by
Sep 18, 2017
Penalty
Initial $11,408 · Current $9,000 Reduced
29 CFR 1910.335(a)(1)(i): Employees working in areas where there are potential electrical hazards shall be provided with, and shall use, electrical protective equipment that is appropriate for the specific parts of the body to be protected and for the work to be performed:            Entire Facility - On or about May 24, 2017, the employer failed to ensure that maintenance employees who performed work on or near energized electrical components, including voltage testing, were provided with and used the following electrical protective equipment to protect their bodies against the hazards of electrocution and arc flash/blast injuries:     1)     Rubber insulating gloves with leather protectors (hands).          2)     Arc-rated long-sleeved shirt and pants or arc-rated coverall          (upper and lower body and extremities)     3)     Arc-rated hard hat or arc-rated flash suit hood (head, impact injury)  4)     Arc-rated face shield with safety glasses or arc-rated flash suit hood (eyes/face)        5)     Arc-rated balaclava or arc-rated flash suit hood (head, burn injury).          6)     Hearing protection - ear canal inserts (hearing).           Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
  • · I (S) $9000
  • · Z (S) $11408

1910.147 C06 II

Other-than-serious 1 instance 6 exposed
Issued
Sep 6, 2017
Abate by
Oct 4, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed:   Entire Facility.  The employer did not certify that periodic inspections of the energy control procedures had been performed at least annually. Employees performed servicing and maintenance on machinery and equipment such as but not limited to plastic injection molding machines and grinders.  Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342349412.