Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BLUEWATER THERMAL SOLUTIONS

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of BLUEWATER THERMAL SOLUTIONS in 337 N BROAD STREET, RIDGWAY, PA 15853 (NAICS 332811). OSHA activity number 342350295.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bluewater Thermal Solutions — free Get an email when a new federal OSHA severe-injury report for Bluewater Thermal Solutions is published. One employer, no account, unsubscribe in one click.
Site address
337 N BROAD STREET
City
RIDGWAY
State
PA
ZIP
15853
Mailing
337 N BROAD STREET, RIDGWAY, PA 15853
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332811
Employees
24
Ownership type
A

3 citations on file for this inspection.

1910.37 A03

Serious Gravity 1 1 instance 6 exposed
Issued
Jun 9, 2017
Penalty
Initial $1,570 · Current $1,178 Reduced
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:    a.)  Bluewater Thermal Solutions, North exit door next to induction unit 21A, on or about May 23rd, 2017 and times prior thereto:  The employees exit route/exit access to the North exit in the production area was obstructed by a Patterson brand 26" industrial fan.
Recent events (2)
  • — I (S) $1177.5
  • — Z (S) $1570

1910.303 B02

Other-than-serious 1 instance 4 exposed
Issued
Jun 9, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    a.) Bluewater Thermal Solutions, area in front of induction machines 21A & 21B, on or about May 23rd, 2017 and times prior thereto:  A "Wind Machine" fan, not designed for industrial locations, was used in the induction heating area to cool employees performing induction machining operations.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 E04

Other-than-serious 1 instance 24 exposed
Issued
Jun 9, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(4): The employer did not make the written hazard communication program available upon request to the Assistant Secretary and the Director  in accordance with 29 CFR 1910.1020(e):     a.)    Bluewater Thermal Solutions, production areas, on or about May 23rd, 2017 and times prior thereto:  Employees worked with and around hazardous substances including, but not limited to, RP-406B (rust preventative solvent), and UCON Quenchant A-NN (quenching fluid).  The employer did not make their Hazard Communication Program available upon request in accordance with 29 CFR 1910.1020(e).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Bluewater Thermal Solutions's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342350295.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.