HUNTINGTON, NY —
OSHA Inspection: DON ANTORINO SEWER & DRAIN INC.
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of DON ANTORINO SEWER & DRAIN INC. in 2 BEECH PLACE, HUNTINGTON, NY 11743 (NAICS 237110). OSHA activity number 342352085.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DON ANTORINO SEWER & DRAIN INC.
- Site address
- 2 BEECH PLACE
- City
- HUNTINGTON
- State
- NY
- ZIP
- 11743
- Mailing
- PO BOX 462, PORT JEFFERSON STATION, NY 11776
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 3
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.100 A
- Issued
- Nov 20, 2017
- Abate by
- Nov 27, 2017
- Penalty
- Initial $3,803 · Current $3,423 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) Worksite, 2 Beech Place, Huntington, NY: Employees engaged in cesspool installation were standing near and underneath bucket operations of a 1979 FMC Link Belt Crane, Model HC78B, Serial # 7DBH2795 without protective helmets ; on or about 5/24/17. Note: In addition to abatement certification, the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (3)
- — F (S) $3422.7
- — C (S) $3803
- — Z (S) $3803
1926.652 A01
- Issued
- Nov 20, 2017
- Abate by
- Nov 27, 2017
- Penalty
- Initial $12,675 · Current $11,408 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c). a) Worksite, 2 Beech Place, Huntington, NY: Employees engaging in cesspool installation (19ft - 20ft deep excavation)were standing approximately 5ft.- 6ft. below grade without being provided with an adequate protective system; on or about 5/24/17. Note: In addition to abatement certification, the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (3)
- — F (S) $11407.5
- — C (S) $12675
- — Z (S) $12675
More inspections at DON Antorino Sewer & Drain INC.
View DON Antorino Sewer & Drain INC.'s full OSHA safety record →
More inspections in this industry (NAICS 237110)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342352085.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.