Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: M & M PLASTICS INC.

Fatality or catastrophe inspection · Safety discipline

On , OSHA opened a fatality or catastrophe safety inspection of M & M PLASTICS INC. in 1320 NW 163RD STREET, MIAMI GARDENS, FL 33169 (NAICS 493110). OSHA activity number 342354412.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch M & M Plastics INC. for free Get an email when a new federal OSHA severe-injury report for M & M Plastics INC. is published. One employer, no account, unsubscribe in one click.
Establishment
M & M PLASTICS INC.
Site address
1320 NW 163RD STREET
City
MIAMI GARDENS
State
FL
ZIP
33169
Mailing
15800 NW 15TH AVENUE, MIAMI, FL 33169
Inspection type
Fatality or catastrophe (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493110
Employees
47
Ownership type
Private (A)

6 citations on file for this inspection.

1910.28 B01 I

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 17, 2017
Abate by
Dec 4, 2017
Penalty
Initial $12,675 · Current $8,873 Reduced
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following:  Guardrail systems, safety net systems, or personal fall arrest systems:      On or about 5/25/2017, an employee was not protected from falling while working from an operator's cabin of a lift truck  (i.e. Crown operator-up high lift order picker, Model #SP3520, Serial # 1A445176) at a height of 15'-3" from floor level.
Recent events (2)
  • · I (S) $8872.5
  • · Z (S) $12675

1910.133 A01

Serious Gravity 1 1 instance 1 exposed
Issued
Nov 17, 2017
Abate by
Nov 27, 2017
Penalty
Initial $3,802 · Current $2,281 Reduced
29 CFR 1910.133(a)(1): Protective eye equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment:    On or about 5/31/2017, an employee was observed nailing pieces of wood without wearing safety glasses with side protection, exposing the employee to the risk of being struck by flying particles.
Recent events (2)
  • · I (S) $2281.2
  • · Z (S) $3802

1910.178 L01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 17, 2017
Penalty
Initial $5,070 · Current $3,042 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    On or about 5/25/2017, at the above addressed worksite, an employee was instructed to operate a lift truck without being trained and/or evaluated, exposing employees to a struck by hazard.
Recent events (2)
  • · I (S) $3042
  • · Z (S) $5070

1910.304 G05

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 17, 2017
Abate by
Dec 4, 2017
Penalty
Initial $5,070 · Current $3,042 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:     On or about 5/31/2017, at the above addressed worksite, a fan lacked a ground prong on its attachment plug, exposing employees to an electrical shock hazard.
Recent events (2)
  • · I (S) $3042
  • · Z (S) $5070

1910.305 G01 IV A

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 17, 2017
Abate by
Dec 4, 2017
Penalty
Initial $5,070 · Current $3,042 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    On or about 5/31/2017, at the above addressed worksite, an electrical extension cord was used while secured to a rack, exposing employees to electrical hazard.
Recent events (2)
  • · I (S) $3042
  • · Z (S) $5070

1910.178 L06

Other-than-serious 1 instance 1 exposed
Issued
Nov 17, 2017
Abate by
Nov 30, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation.  On or about 5/25/2017, at the above addressed worksite, an employee was instructed to operate a lift truck without being certified, exposing employees to a struck by hazard.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View M & M Plastics INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342354412.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.