Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SUNFLOWER ELECTRIC POWER CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SUNFLOWER ELECTRIC POWER CORPORATION in 14255 EAST US 160 HWY, ULYSSES, KS 67880 (NAICS 221122). OSHA activity number 342355997.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sunflower Electric Power Corporation — free Get an email when a new federal OSHA severe-injury report for Sunflower Electric Power Corporation is published. One employer, no account, unsubscribe in one click.
Site address
14255 EAST US 160 HWY
City
ULYSSES
State
KS
ZIP
67880
Mailing
PO BOX 1020 301 W 13TH, HAYS, KS 67601
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
221122
Employees
8
Ownership type
A

2 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 6, 2017
Abate by
Aug 1, 2017
Penalty
Initial $9,054 · Current $9,054
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  An employee operating machinery in the machine shop was exposed to amputation hazards, flying chips and rotating parts, in that guarding was not in place to prevent struck-by and caught in hazards:  a) 7-inch Horizontal Band Saw (Model HVBS-7MW SN WJ 4777) missing Blade Guard (Part #HVBS7MW)  b) Westward 12-inch Drill Press (Model 1KEN7) missing safety shield
Recent events (1)
  • — Z (S) $9054

1910.215 B09

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 6, 2017
Abate by
Aug 1, 2017
Penalty
Initial $5,432 · Current $5,432
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one-fourth inch:  An employee engaged in operating an 8 inch DeWALT bench grinder (Model DW758, SN 2013 26-YL92138) in the machine shop was exposed to struck-by hazards, in that the adjustable tongue was secured at approximately 1/2inch  above the peripheral wheel.
Recent events (1)
  • — Z (S) $5432

View Sunflower Electric Power Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342355997.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.