BROKEN ARROW, OK —
OSHA Inspection: OSCAR MORENO-VASQUEZ
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of OSCAR MORENO-VASQUEZ in 901 E TACOMA ST., BROKEN ARROW, OK 74012 (NAICS 238160). OSHA activity number 342358868.
Where did this inspection happen?
- Establishment
- OSCAR MORENO-VASQUEZ
- Site address
- 901 E TACOMA ST.
- City
- BROKEN ARROW
- State
- OK
- ZIP
- 74012
- Mailing
- 2732 S 130TH EAST AVE., TULSA, OK 74134
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B13
- Issued
- Abate by
- Penalty
- Initial $2173.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: On or about May 25, 2017, the employer did not ensure employees performing roofing work activities were in use of fall protection. The employees were exposed to a fall hazard.
Recent events (2)
- — I (S) $1000
- — Z (S) $2173
1926.1053 B01
- Issued
- Penalty
- Initial $1630.00 · Current $800.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed. On or about May 25, 2017, the employer did not ensure an extension ladder being used by employees was extended at least 3 feet above the landing, exposing the employees to a fall hazard.
Recent events (2)
- — I (S) $800
- — Z (S) $1630
More inspections in this industry (NAICS 238160)
SIOUX FALLS, SD—2026-07-13
H & R ROOFING OF SOUTH DAKOTA, INC.
HENDERSON, NV—2026-07-13
INTEGRITY ROOFING LLC
CORTLANDT MANOR, NY—2026-07-13
LG BUILDERS INC.
CAMDEN, OH—2026-07-13
ALBERTO MORALES
BLOOMINGTON, IL—2026-07-13
UNKNOWN CONTRACTOR
More inspections in OK
MADILL, OK—2026-07-08
MID AMERICAN STEEL & WIRE CO., LLC
SEILING, OK—2026-06-26
GORE ENERGY
ADA, OK—2026-06-25
PAN AMERICA ELECTRIC , INC.
ADA, OK—2026-06-25
CITATION OIL & GAS CORPORATION
EDMOND, OK—2026-06-23
BRICK EXPERTS INC.
Source