SAINT LOUIS, MO ·
OSHA Inspection: GATEWAY SERVICE CENTER
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of GATEWAY SERVICE CENTER in 8000 HALL ST., SAINT LOUIS, MO 63147 (NAICS 811111). OSHA activity number 342363850.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GATEWAY SERVICE CENTER
- Site address
- 8000 HALL ST.
- City
- SAINT LOUIS
- State
- MO
- ZIP
- 63147
- Mailing
- 699 STATE RT. 203, SUITE A, EAST SAINT LOUIS, IL 62201
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811111
- Employees
- 20
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
5(a)(1)
- Issued
- Nov 14, 2017
- Abate by
- Jan 3, 2018
- Penalty
- Initial $3,622 · Current $2,600 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employee(s) in that employee(s) were exposed to the hazard of: a. Being struck by exploding pieces of PVC plastic piping while being used to convey compressed air during the servicing of trucks, including the use of air powered tools and inflation of tires. Among other methods, feasible and recommended abatement could be: Use piping designed for conveying compressed air. Abatement documentation is required for this violation.
Recent events (2)
- · I (S) $2600
- · Z (S) $3622
1910.169 B02
- Issued
- Nov 14, 2017
- Penalty
- Initial $5,070 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.169(b)(2): Air receiver(s) were not drained frequently and at such intervals as to prevent the accumulation of excessive amounts of liquid in the receiver: a. On the compressor air tank mounted in the GMC service truck there the drain valve was not drained frequently to prevent the accumulation of liquid and particulates. Abatement documentation is required for this violation.
Recent events (2)
- · I (S) $3500
- · Z (S) $5070
1910.169 B03 IV
- Issued
- Nov 14, 2017
- Penalty
- Initial $5,070 · Current $3,500 Reduced
General-duty citation text
29 CFR 1910.169(b)(3)(iv): Safety valve(s) on compressed air receiver(s) were not tested at frequently regular intervals to determine if they were in good operating condition: a. On the compressor air tank mounted in the GMC service truck, a pressure relief valve was not tested frequently and at regular intervals. Abatement documentation is required for this violation.
Recent events (2)
- · I (S) $3500
- · Z (S) $5070
1910.219 B01
- Issued
- Nov 14, 2017
- Abate by
- Jan 3, 2018
- Penalty
- Initial $2,173 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.219(b)(1): Flywheel(s) with parts seven feet or less above floor(s) or platform(s) were not guarded in accordance with the requirements specified in 29 CFR 1910.219(b)(1)(i) through (b)(1)(iv): a. The compressor mounted in the GMC service truck was operated without a guard over the flywheel, belt, and pulley. Abatement documentation is required for this violation.
Recent events (2)
- · I (S) $1400
- · Z (S) $2173
1910.219 D01
- Issued
- Nov 14, 2017
- Abate by
- Jan 3, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a. The compressor mounted in the GMC service truck was operated without a guard over the flywheel, belt, and pulley. Abatement documentation is required for this violation.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.219 E01 I
- Issued
- Nov 14, 2017
- Abate by
- Jan 3, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs 42 inches or less from the floor level were not fully enclosed by guards conforming to requirements specified in 29 CFR 1910.219(m) and (o): a. The compressor mounted in the GMC service truck was operated without a guard over the flywheel, belt, and pulley. Abatement documentation is required for this violation.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections at Gateway Service Center
View Gateway Service Center's full OSHA safety record →
More inspections in this industry (NAICS 811111)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342363850.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.