SAVANNAH, GA —
OSHA Inspection: CDM SMITH, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CDM SMITH, INC. in HUTCHINSON ISLAND, SAVANNAH, GA 31421 (NAICS 237990). OSHA activity number 342363918.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CDM SMITH, INC.
- Site address
- HUTCHINSON ISLAND
- City
- SAVANNAH
- State
- GA
- ZIP
- 31421
- Mailing
- 131 HUTCHINSON ISLAND RD., SAVANNAH, GA 31421
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237990
- Employees
- 9
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.350 A10
- Issued
- Jul 14, 2017
- Penalty
- Initial $4,889 · Current $3,889 Reduced
General-duty citation text
29 CFR 1926.350(a)(10): Oxygen cylinders in storage were not separated from fuel-gas cylinder or combustible materials (especially oil or grease), a minimum distance of 20 feet or by a noncombustible barrier at least 5 feet high having a fire-resistance rating of at least one-half hour: A) Job site, on or about May 30, 2017, an oxygen gas cylinder was stored approximately 3 feet away from Liquefied Petroleum (LP) gas cylinders, exposing employees to fire hazard.
Recent events (2)
- — I (O) $3889
- — Z (S) $4889
1926.1437 E01
- Issued
- Jul 14, 2017
- Abate by
- Aug 9, 2017
- Penalty
- Initial $6,111 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.1437(e)(1): Barge, pontoon, vessel or other means of flotation did not have a list and trim device located in the cab or at the operator's station: A) On the barge, on or about May 30, 2017, the employer did not have a list and trim device inside the cab of the crane, exposing employees to a hazard of drowning or being struck by material when operating the crane.
Recent events (2)
- — I (O) $1000
- — Z (S) $6111
1926.152 G09
- Issued
- Jul 14, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.152(g)(9): Conspicuous and legible signs prohibiting smoking were not posted in service and refueling areas: A) On the barge, on or about May 25, 2017, a 200 gallon metal tank containing diesel fuel used to refill equipment did not have a No Smoking sign posted.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 F06
- Issued
- Jul 14, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(6): Except as provided in paragraphs (f)(7) and (f)(8) of this section, the employer did not ensure that each container of hazardous chemicals in the workplace is labeled, tagged or marked according to sections (f)(6)(i) or (f)(6)(ii): A) On the barge, on or about May 25, 2017, a 200 gallon metal tank containing diesel fuel was not labeled as to its contents or hazard warning.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at CDM Smith, INC.
View CDM Smith, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 237990)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342363918.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.