AMMON, ID —
OSHA Inspection: TWO BROTHERS CONSTRUCTION AND RENOVATION, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TWO BROTHERS CONSTRUCTION AND RENOVATION, INC. in PINFIRE CREEK, AMMON, ID 83406 (NAICS 238130). OSHA activity number 342364247.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TWO BROTHERS CONSTRUCTION AND RENOVATION, INC.
- Site address
- PINFIRE CREEK
- City
- AMMON
- State
- ID
- ZIP
- 83406
- Mailing
- 4382 N. HAROLDSEN DR. SUITE B8, IDAHO FALLS, ID 83401
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 35
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.451 A06
- Issued
- Jul 14, 2017
- Abate by
- Aug 9, 2017
- Penalty
- Initial $8,873 · Current $8,873
General-duty citation text
29 CFR 1926.451(a)(6): Scaffolds were not designed by a qualified person: (a) Pinfire Creek: On or about May 22, 2017 and at times prior, at approximately 18 ft. employees were working from a 12 ft. x 4 ft. platform that was being lifted by a JLG Skytrak rough terrain forklift. The employees were sheeting an exterior wall of a single family home. (b) Pinfire Creek: On or about June 14, 2017 and at times prior, at approximately 22 ft. employees were working from a 12 ft. x 4 ft. platform that was being lifted by a JLG Skytrak rough terrain forklift. The employees were installing fascia of a single family home. Note: Abatement documentation and certification required for this item.
Recent events (3)
- — A (S) $8873
- — I (S) $3200
- — Z (S) $8873
1926.451 C02 IV
- Issued
- Jul 14, 2017
- Abate by
- Aug 9, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(2)(iv): Front-end loaders and similar pieces of equipment were used to support scaffold platforms when they were not specifically designed by the manufacturer for such use: (a) Pinfire Creek: On or about May 22, 2017 and at times prior, at approximately 18 ft. employees were working from a 12 ft. x 4 ft. platform that was being lifted by a JLG Skytrak rough terrain forklift. The employees were sheeting an exterior wall of a single family home. (b) Pinfire Creek: On or about June 14, 2017 and at times prior, at approximately 22 ft. employees were working from a 12 ft. x 4 ft. platform that was being lifted by a JLG Skytrak rough terrain forklift. The employees were installing fascia of a single family home. Note: Abatement documentation and certification is required.
Recent events (3)
- — A (S) $0
- — I (S) $0
- — Z (S) $0
1926.451 C02 V
- Issued
- Jul 14, 2017
- Abate by
- Aug 9, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(2)(v): Fork-lifts were used to support scaffold platforms while the entire platform was not attached to the fork and the fork-lift was moved horizontally while the platform was occupied: (a) Pinfire Creek: On or about May 22, 2017 and at times prior, at approximately 18 ft. employees were working from a 12 ft. x 4 ft. platform that was being lifted by a JLG Skytrak rough terrain forklift. The employees were sheeting an exterior wall of a single family home. Note: Abatement documentation and certification is required for this item.
Recent events (3)
- — A (S) $0
- — I (S) $0
- — Z (S) $0
1926.451 G01
- Issued
- Jul 14, 2017
- Abate by
- Aug 9, 2017
- Penalty
- Initial $8,873 · Current $8,873
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: (a) Pinfire Creek: On or about May 22, 2017 and at times prior, at approximately 18 ft. employees were working from a 12 ft. x 4 ft. platform that was being lifted by a JLG Skytrak rough terrain forklift. The employees were sheeting an exterior wall of a single family home. (b) Pinfire Creek: On or about June 14, 2017 and at times prior, at approximately 22 ft. employees were working from a 12 ft. x 4 ft. platform that was being lifted by a JLG Skytrak rough terrain forklift. The employees were installing fascia of a single family home. Note: Abatement documentation and certification is required for this item.
Recent events (3)
- — A (S) $8873
- — I (S) $3200
- — Z (S) $8873
1926.602 D
- Issued
- Jul 14, 2017
- Abate by
- Aug 9, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.602(d): The employer did not ensure that each employee operating a powered industrial vehicle had been trained and evaluated as required by paragraph 29 CFR 1910.178(l): Note: The requirements applicable to construction work under paragraph (d) of this section are identical to those set forth at paragraph (l) of 29 CFR 1910.178. and as referenced by the note contained in 1926.602(d). (a) Pinfire Creek: On or about May 22, 2017 and at times prior, at approximately 18 ft. employees were working from a 12 ft. x 4 ft. platform that was being lifted by a JLG Skytrak rough terrain forklift. The employees were sheeting an exterior wall of a single family home. Note: Abatement documentation and certification is required for this item.
Recent events (3)
- — A (S) $0
- — I (S) $0
- — Z (S) $0
1926.501 B13
- Issued
- Jul 14, 2017
- Abate by
- Aug 9, 2017
- Penalty
- Initial $8,873 · Current $8,873
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): (a) Pinfire Creek: On or about June 14, 2017 and at times prior, at approximately 22 ft. employees were walking along the top plate of a single family home. Note: Abatement certification and documentation is required for this item.
Recent events (3)
- — A (S) $8873
- — I (S) $3200
- — Z (S) $8873
More inspections at TWO Brothers Construction and Renovation, INC.
View TWO Brothers Construction and Renovation, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342364247.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.