Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,193,745Inspections Most recent open 2026-08-06 Last loaded 2026-08-10

OSHA Inspection: RICO ROCK, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of RICO ROCK, INC. in 205 E IH 10, SEGUIN, TX 78155 (NAICS 327999). OSHA activity number 342367828.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rico Rock, INC. for free Get an email when a new federal OSHA severe-injury report for Rico Rock, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
RICO ROCK, INC.
Site address
205 E IH 10
City
SEGUIN
State
TX
ZIP
78155
Mailing
205 E IH 10, SEGUIN, TX 78155
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327999
Employees
10
Ownership type
A

5 citations on file for this inspection.

1910.134 C01

Serious Gravity 5 1 instance 10 exposed
Issued
Aug 30, 2017
Abate by
Sep 19, 2017
Penalty
Initial $2,716 · Current $1,630 Reduced
29 CFR 1910.134(c)(1): The employer did not establish and implement a written respiratory protection program with worksite-specific procedures in the workplace where respirators were necessary to protect the health of the employee or whenever respirators were required by the employer:  On or about 1 June 2017, and at times prior, the employer did not ensure that each of the following provisions were established and implemented in the respiratory protection program where employees are required to wear respirators:  1910.134(c)(1)(i)-Procedures for selecting respirators for use in the workplace;  1910.134(c)(1)(ii)-Medical evaluations of employees required to use respirators;  1910.134(c)(1)(iii)-Fit testing procedures for tight-fitting respirators;  1910.134(c)(1)(iv)-Procedures for proper use of respirators in routine and reasonably foreseeable emergency situations;  1910.134(c)(1)(v)-Procedures and schedules for cleaning, disinfecting, storing, inspecting, repairing, discarding and otherwise maintaining respirators;  1910.134(c)(1)(vi)-Procedures to ensure adequate air quality, quantity, and flow of breathing air for atmosphere-supplying respirators; 1910.134(c)(1)(vii)-Training of employees in the respiratory hazards to which they are potentially exposed during routine and emergency situations;  1910.134(c)(1)(viii)-Training of employees in the proper use of respirators, including putting on and removing the, any limitations on their use, and their maintenance; and 1910.134(c)(1)(xi)-Procedures for regularly evaluating the effectiveness of the program
Recent events (2)
  • · I (S) $1629.6
  • · Z (S) $2716

1910.304 G05

Serious Gravity 1 1 instance 4 exposed
Issued
Aug 30, 2017
Penalty
Initial $1,630 · Current $978 Reduced
29 CFR 1910.304(g)(5): Grounding path. The path to ground from circuits, equipment, and enclosures were not permanent, continuous, and effective:  On or about 1 June 2017, in the shooting area, the fan being used by employees to provide ventilation did not have a grounding prong, exposing them to electrical hazards.
Recent events (2)
  • · I (S) $978
  • · Z (S) $1630

1910.305 G02 III

Serious Gravity 1 1 instance 2 exposed
Issued
Aug 30, 2017
Penalty
Initial $1,630 · Current $978 Reduced
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to the joints or terminal screws:  On or about 1 June 2017, a flexible cord being used by employees to power a fan in the shooting area of the facility did not have strain relief,  exposing the wires inside and exposing employee working nearby to electrical hazards.
Recent events (2)
  • · I (S) $978
  • · Z (S) $1630

1910.1000 C

Serious Gravity 5 2 instances 4 exposed
Issued
Aug 30, 2017
Abate by
Sep 19, 2017
Penalty
Initial $2,716 · Current $1,630 Reduced
29 CFR 1910.1000(c): Employee(s) were exposed to silica, crystalline quartz (respirable) listed in Table Z-3, in excess of 10 mg/m3 / %SiO2 + 2 as an 8 hour Time-Weighted Average concentration:  On or about 8 June 2017 and at times prior thereto, employee(s) working in the shooting area of the shop were exposed to respirable dust exposing them to respiratory hazards.  a) One employee was exposed to dust containing 15% crystalline silica (quartz) at an 8-hour Time Weighted Average of 1.08mg/m3, which is approximately 1.8 times the Permissible Exposure Limit of  0.588mg/m3. The exposure level is derived from a sample collected over a 469 minute period and the calculations include a zero value for the 11 minutes not sampled.  b) One employee was exposed to dust containing 12% crystalline silica (quartz) at an 8-hour Time Weighted Average of 1.678mg/m3, which is approximately 2.35 times the Permissible Exposure Limit of  0.714mg/m3. The exposure level is derived from a sample collected over a 474 minute period and the calculations include a zero value for the 6 minutes not sampled.
Recent events (2)
  • · I (S) $1629.6
  • · Z (S) $2716

1910.1200 E01

Serious Gravity 5 1 instance 10 exposed
Issued
Aug 30, 2017
Abate by
Sep 19, 2017
Penalty
Initial $2,173 · Current $1,304 Reduced
29 CFR 1910.1200(e)(1): Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:  On or about 1 June 2017, the employer did not have a written hazard communication program implemented at the worksite where employees were mixing and spraying chemicals used in the production of rock waterfalls.
Recent events (2)
  • · I (S) $1303.8
  • · Z (S) $2173

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342367828.