LANCASTER, PA —
OSHA Inspection: KAUTZ CONSTRUCTION COMPANY
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of KAUTZ CONSTRUCTION COMPANY in 10 SOUTH PRINCE STREET, LANCASTER, PA 17603 (NAICS 238160). OSHA activity number 342368321.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KAUTZ CONSTRUCTION COMPANY
- Site address
- 10 SOUTH PRINCE STREET
- City
- LANCASTER
- State
- PA
- ZIP
- 17603
- Mailing
- 1278 LOOP ROAD #D, LANCASTER, PA 17601
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 5
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.150 C01 I
- Issued
- Jun 23, 2017
- Abate by
- Jul 20, 2017
- Penalty
- Initial $2,390 · Current $2,390
General-duty citation text
29 CFR 1926.150(c)(1)(i): A fire extinguisher, rated not less than 2A, was not provided for each 3,000 square ft. of the protected building area, or major fraction thereof: a) 10 South Prince Street, Lancaster PA; Roof - Employees using gas powered equipment and portable electric power tools did not have a portable fire extinguisher available as required, on or about June 1, 2017. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $2390
- — Z (S) $2390
1926.252 A
- Issued
- Jun 23, 2017
- Abate by
- Jul 20, 2017
- Penalty
- Initial $3,187 · Current $0 Reduced
General-duty citation text
29 CFR 1926.252(a): An enclosed chute of wood, or equivalent material, was not used where materials were dropped more than 20 feet to points lying outside the exterior walls of the building(s): a) 10 South Prince Street, Lancaster PA; Roof - Employees were observed dropping roofing materials from the edge of a roof approximately 30 feet high to a dumpster below without using an enclosed cute, on or about June 1, 2017. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $3187
1926.501 B10
- Issued
- Jun 23, 2017
- Penalty
- Initial $11,154 · Current $10,163 Reduced
General-duty citation text
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs with unprotected sides and edges 6 feet or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest systems, or a combination of warning line system and guardrail system, warning line system and safety net system, or warning line system and personal fall arrest system, or warning line system and safety monitoring system. Or, on roofs 50-feet (15.25 m) or less in width, each employee was not protected by use of a monitoring system: a) 10 South Prince Street, Lancaster PA; Roof - Employees conducting roofing operations used a ramp placed at the parapet wall to throw roofing debris over the edge of the roof without the use of fall protection and were exposed to an approximate 30 foot fall hazard to the ground below, on or about June 1, 2017. No abatement certification or documentation required. Kautz Construction Company was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(10), which was contained in OSHA inspection number 1078030, citation number 1, item number 1 and was affirmed as a final order on October 2, 2015, with respect to a workplace located at 1861 Catasauqua Road, Bethlehem Pennsylvania 18017.
Recent events (2)
- — I (S) $10163
- — Z (R) $11154
1926.503 B01
- Issued
- Jun 23, 2017
- Abate by
- Jul 20, 2017
- Penalty
- Initial $447 · Current $447
General-duty citation text
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section (fall protection training) by preparing a written certification record which contained the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer: a) 10 South Prince Street, Lancaster PA; Roof - The employer did not prepare a written certification verifying that employees had been trained in hazards related to falls from elevation, on or about June 1, 2017. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $447
- — Z (O) $447
More inspections at Kautz Construction Company
View Kautz Construction Company's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342368321.