Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,195,903Inspections Most recent open 2026-08-18 Last loaded 2026-08-21

OSHA Inspection: ASAP FABRICATION INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ASAP FABRICATION INC. in 5340 W US HIGHWAY 92, PLANT CITY, FL 33566 (NAICS 332996). OSHA activity number 342371762.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Asap Fabrication INC. for free Get an email when a new federal OSHA severe-injury report for Asap Fabrication INC. is published. One employer, no account, unsubscribe in one click.
Site address
5340 W US HIGHWAY 92
City
PLANT CITY
State
FL
ZIP
33566
Mailing
5340 W US HIGHWAY 92, PLANT CITY, FL 33566
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Case closed
Last modified
Data loaded
NAICS code
332996
Employees
9
Ownership type
Private (A)

9 citations on file for this inspection.

1910.95 C01

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 21, 2017
Abate by
Nov 8, 2017
Penalty
Initial $2,716 · Current $1,630 Reduced

Hazardous substances 8111

29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent:  a)  In the fabrication shop, the cut - off saw operator was exposed to continuous noise levels at 267% of the allowable 8 hour TWA-Action Limit (85 dBA).  The equivalent dBA level of 267% is 97.08 dBA.  The sampling was performed for 374 minutes during one shift on August 3, 2017.
Recent events (2)
  • · I (S) $1629.6
  • · Z (S) $2716

1910.147 C01

Serious Gravity 5 1 instance 5 exposed
Issued
Sep 21, 2017
Abate by
Nov 8, 2017
Penalty
Initial $2,716 · Current $1,630 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:   (a)  At the fabrication areas, for employees authorized to do repair and / or maintenance of machines such as but not limited to the Lehman, LeBlond, American 20 x 144 and American Engine lathes, as observed on or about 6/1/2017.
Recent events (2)
  • · I (S) $1629.6
  • · Z (S) $2716

1910.184 D

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 21, 2017
Abate by
Oct 18, 2017
Penalty
Initial $2,173 · Current $1,304 Reduced
29 CFR 1910.184(d): Sling(s) and fastenings were not inspected each day or during use and were not removed from service when damaged or defective:  (a) At the fabrication shop, or the synthetic web slings used to load pipe onto the Progress-Jones I-820 lathe, as observed on or about 6/1/2017.
Recent events (2)
  • · I (S) $1303.8
  • · Z (S) $2173

1910.184 I01

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 21, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.184(i)(1): Synthetic web sling(s) were not marked or coded to show rated capacities for each type of hitch and type of synthetic web material:  (a) At the fabrication shop, or the synthetic web slings used to load pipe onto the Progress-Jones I-820 lathe, as observed on or about 6/1/2017.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.184 I09 III

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 21, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.184(i)(9)(iii): Synthetic web sling(s) with snags, punctures, tears, or cuts were not immediately removed from service:  (a) At the fabrication shop, or the synthetic web slings used to load pipe onto the Progress-Jones I-820 lathe, as observed on or about 6/1/2017.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 D02

Serious Gravity 5 1 instance 1 exposed
Issued
Sep 21, 2017
Penalty
Initial $2,309 · Current $1,385 Reduced
29 CFR 1910.305(d)(2): Panel boards were not mounted in cabinets, cutout boxes, or enclosures approved for the purpose and were not dead front:  (a) For 480V 3-Phase electrical panel board located in the welding area of the iron pipe fabrication shop, as observed on or about 6/1/2017.
Recent events (2)
  • · I (S) $1385.4
  • · Z (S) $2309

1910.134 C02 II

Other-than-serious 1 instance 1 exposed
Issued
Sep 21, 2017
Abate by
Oct 18, 2017
Penalty
Initial $0 · Current $0

Hazardous substances 1080201020372590

29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user:  (a) For employees at the ductile iron pipe fabrication shop painting areas provided with tight-fitting face piece respirators, such as but not limited to, 3M Half face piece Organic Vapor Cartridge 6001 and 3M Half Face piece Disposable Respirator Assembly 5101-Organic Vapor for voluntary use, as observed on or about 8/3/2017.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.134 K06

Other-than-serious 1 instance 1 exposed
Issued
Sep 21, 2017
Abate by
Oct 18, 2017
Penalty
Initial $0 · Current $0

Hazardous substances 1080201020372590

29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer:  (a) For employees at the ductile iron pipe fabrication shop painting areas provided with filtering face piece respirators such as but not limited to 3M Particulate Respirator N95 (8511) and tight-fitting face piece respirators, such as but not limited to, 3M Half face piece Organic Vapor Cartridge 6001 and 3M Half Face piece Disposable Respirator Assembly 5101-Organic Vapor for voluntary use, as observed on or about 8/3/2017.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

1910.1200 H01

Other-than-serious 1 instance 6 exposed
Issued
Sep 21, 2017
Abate by
Oct 18, 2017
Penalty
Initial $0 · Current $0

Hazardous substances 10802010203725872590

29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  (a) For employees at the ductile iron pipe fabrication shop handling asphalt paint, primers and ductile iron pipe, as observed on or about 8/3/2017.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342371762.