Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: FRESH EXPRESS INCORPORATED

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of FRESH EXPRESS INCORPORATED in 1109 E. LAKE STREET, STREAMWOOD, IL 60107 (NAICS 311999). OSHA activity number 342375649.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fresh Express Incorporated for free Get an email when a new federal OSHA severe-injury report for Fresh Express Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
1109 E. LAKE STREET
City
STREAMWOOD
State
IL
ZIP
60107
Mailing
1109 E. LAKE STREET, STREAMWOOD, IL 60107
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311999
Employees
700
Ownership type
Private (A)

1 citation on file for this inspection.

1910.119 D03 II

Serious Gravity 10 1 instance 15 exposed
Issued
Sep 28, 2017
Abate by
Nov 27, 2017
Penalty
Initial $11,408 · Current $6,845 Reduced

Hazardous substances 0170

29 CFR 1910.119(d)(3)(ii): The employer did not document that equipment complies with recognized and generally accepted good engineering practices.     (a) Fresh Express Incorporated, at 1109 E. Lake Street, Streamwood, Illinois: On or about June 5, 2017, the employer failed to determine and document that the anhydrous ammonia refrigeration system was adequately designed, installed, and maintained to protect employees from an uncontrolled release of anhydrous ammonia in compliance with recognized and generally accepted good engineering practices (RAGAGEP). The evaporator condenser containing (EV-12) anhydrous ammonia in the pack out area was installed unprotected, immediately adjacent to the mezzanine used by powered industrial trucks. Anhydrous ammonia was released on June 5, 2017 when the unprotected evaporator condenser (EV-12) was struck by a powered industrial truck delivering materials to the mezzanine area.    Among other methods, a feasible abatement method to correct this hazard is to ensure that the ammonia refrigeration system is adequately designed, installed, and maintained in compliance with a RAGAGEP such as the ANSI/ASHRAE-15 2016, Safety Standard for Refrigeration Systems, Section 11.1 General Restrictions - Safeguards: "Means shall be taken to adequately safeguard piping, controls, and other refrigerating equipment to minimize possible accidental damage or rupture by external sources."
Recent events (2)
  • · I (S) $6845
  • · Z (S) $11408

View Fresh Express Incorporated's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342375649.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.