MUSKEGON, MI —
OSHA Inspection: DEPARTMENT OF TRANSPORTATION, FEDERAL AVIATION ADMINISTRATION, AIR TRAFFIC ORGANIZATION, MUSKEGON ATCT/TRACON
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DEPARTMENT OF TRANSPORTATION, FEDERAL AVIATION ADMINISTRATION, AIR TRAFFIC ORGANIZATION, MUSKEGON ATCT/TRACON in 113 SINCLAIR DR., MUSKEGON, MI 49441 (NAICS 488111). OSHA activity number 342377124.
Where did this inspection happen?
- Establishment
- DEPARTMENT OF TRANSPORTATION, FEDERAL AVIATION ADMINISTRATION, AIR TRAFFIC ORGANIZATION, MUSKEGON ATCT/TRACON
- Site address
- 113 SINCLAIR DR.
- City
- MUSKEGON
- State
- MI
- ZIP
- 49441
- Mailing
- 4695 44TH ST. SE SUITE B-120, GRAND RAPIDS, MI 49512
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 488111
- Employees
- 39
- Ownership type
- D
Citations
4 citations on file for this inspection.
1910.28 B03 IV
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.28(b)(3)(iv) as require by 1960.8(b): The employer did not ensure each employee was protected from falling into a ladderway floor hole or ladderway platform hole by a guardrail system and toeboards erected on all exposed sides, except at the entrance to the hole, where a self-closing gate or an offset must be used. On or about June 5, 2017, in the boiler room, a floor opening access leading down to the elevator control room was not guarded with a guardrail system, there by exposing employees to a fall hazard.
Recent events (1)
- — Z (S) $0
1910.303 G01 II
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(1)(ii) as required by 1960.8 (b): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: On or about June 6, 2017, in the TELCO room, employees were exposed to electrical hazards in that work space in front of electrical panels was used for storage of large box containing a Cathode ray tube (CRT). Employer did not provide and maintain sufficient access which could hinder the ready and safe operation and maintenance of equipment.
Recent events (1)
- — Z (S) $0
1910.305 A02 IX
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(a)(2)(ix) as require by 1960.8(b): All lamps for general illumination shall be protected from accidental contact or breakage by a suitable fixture or lampholder with a guard. Brass shell, paper-lined sockets, or other metal-cased sockets may not be used unless the shell is grounded. On or about June 6, 2017, in the tower stairwell near the fourth floor, a 26 watt CFL which contained mercury was used to illuminate the stairwell was not guarded to prevent accidental contact or breakage there by exposing employees to an electrical shock and mercury hazards.
Recent events (1)
- — Z (S) $0
1910.1200 G01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(g)(1) as required by 1960.8(b): The employer did not have a safety data sheet (SDS) for each hazardous chemical in use: On or about June 6, 2017, in the mechanical room, employees were required to use Lubricating Oil and SDSs for the chemical was not available. Employees were exposed to ingestion, eye, and skin contact hazards that could result in health effects such as, but not limited to irritation of mucous membranes eyes, and skin.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 488111)
ANCHORAGE, AK—2026-01-27
DEPT. OF TRANSPORTATION - FAA
ST THOMAS, VI—2025-12-19
FAA-ST THOMAS ATCT
KINGSHILL, VI—2025-12-11
ROBINSON AVIATION INC
MATHER, CA—2025-11-11
ROBINSON AVIATION, INC.
DETROIT, MI—2025-07-24
WAYNE COUNTY AIRPORT AUTHORITY
More inspections in MI
FLINT, MI—2026-07-16
WILDFIRE INVESTMENT LLC
MUSKEGON, MI—2026-07-16
TIMBERLAND CHARTER ACADEMY
ROCHESTER HILLS, MI—2026-07-16
LEAR CORPORATION DBA EAGLE OTTAWA
ROCHESTER HILLS, MI—2026-07-16
ICON RESTORATION SERVICES
WOODHAVEN, MI—2026-07-16
G.J. PERELLI CO., L.L.C.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342377124.