WASHINGTON, DC —
OSHA Inspection: DIEGO LOPEZ
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DIEGO LOPEZ in 3827 ALBERMARLE STREET NW, WASHINGTON, DC 20015 (NAICS 238130). OSHA activity number 342378353.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DIEGO LOPEZ
- Site address
- 3827 ALBERMARLE STREET NW
- City
- WASHINGTON
- State
- DC
- ZIP
- 20015
- Mailing
- 8127 15TH AVE. APT 104, HYATTSVILLE, MD 20783
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 4
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.501 B13
- Issued
- Jul 19, 2017
- Abate by
- Jul 27, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) On or about April 26, 2017; Second floor area of new residential construction; employees were observed working near the unguarded edges of the residential home without fall protection in place to protect them from falling an estimated 27-30 feet to ground level while installing the trusses. b) On or about April 26, 2017; Second floor area of new residential construction; employees were observed working near openings of the residential home without fall protection in place to protect them from falling an estimated 27-30 feet to ground level while conducting carpentry work. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $3803
1926.1053 B01
- Issued
- Jul 19, 2017
- Abate by
- Jul 27, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On or about April 26, 2017; Second floor area of new residential construction; employees were using an extension ladder to access the work area, which was extended 18 inches above the working platform (deck), exposing them to an estimated 25 foot fall to ground level. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $3803
1926.1053 B13
- Issued
- Jul 19, 2017
- Abate by
- Jul 27, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step a) On or about April 26, 2017; Second floor area of new residential construction; employees were using the top step of an 8-foot step ladder to access the work area, which was located 10-feet from the floor (deck), exposing them to a 10 foot fall to the wooden floor area. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the Certification of Corrective Action Worksheet), in addition, documentation demonstrating the abatement is complete must be included with your certification. This documentation may include, but is not limited to evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.
Recent events (1)
- — Z (S) $3803
More inspections at Diego Lopez
View Diego Lopez's full OSHA safety record →
More inspections in this industry (NAICS 238130)
More inspections in DC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342378353.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.