NEW YORK, NY —
OSHA Inspection: PATRICIO SANCHEZ
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of PATRICIO SANCHEZ in 78 LEONARD STREET, NEW YORK, NY 10013 (NAICS 238120). OSHA activity number 342379286.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PATRICIO SANCHEZ
- Site address
- 78 LEONARD STREET
- City
- NEW YORK
- State
- NY
- ZIP
- 10013
- Mailing
- 5224 3RD AVENUE C/O UNIVERSAL CONSTRUCTION, BROOKLYN, NY 11220
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- Employees
- 2
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.303 B01
- Issued
- Oct 17, 2017
- Abate by
- Oct 27, 2017
- Penalty
- Initial $2,173 · Current $2,173
General-duty citation text
29 CFR 1926.303(b)(1): Grinding machines were not equipped with safety guards in conformance with the requirements of ANSI B7.1-1970, Safety Code for the Use, Care, and Protection of abrasive wheels, and paragraph (d) of this section: a) On or about 5/11/2017, Basement area: An angle grinder was being used without a guard. Abatement certification is required for this item.
Recent events (1)
- — Z (S) $2173
1926.403 B01 I
- Issued
- Oct 17, 2017
- Abate by
- Oct 27, 2017
- Penalty
- Initial $2,173 · Current $2,173
General-duty citation text
29 CFR 1926.403(b)(1)(i): Safety of equipment was not determined on the basis of suitability of the equipment for an identified purpose as evidenced by listing, labeling, or certification for that identified purpose. a) On or about 5/11/2017, Basement area: An electric outlet was being used which was mounted in a metal box that was not secured to the structure. Abatement certification is required for this item.
Recent events (1)
- — Z (S) $2173
1926.403 B01 II
- Issued
- Oct 17, 2017
- Abate by
- Oct 27, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(b)(1)(ii): Safety of equipment was not determined on the basis of mechanical strength and durability, including, for parts designed to enclose and protect other equipment, the adequacy of the protection thus provided: a) On or about 5/11/2017, Basement area: An electric outlet was being used which was mounted in a metal box that had damaged strain relief. Abatement certification is required for this item.
Recent events (1)
- — Z (S) $0
1926.404 B01 I
- Issued
- Oct 17, 2017
- Abate by
- Oct 27, 2017
- Penalty
- Initial $2,173 · Current $2,173
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: a) On or about 5/11/2017, Basement area: Electrical equipment was in use with out the protection of an assured equipment grounding program or an operational GFCI. Abatement certification is required for this item.
Recent events (1)
- — Z (S) $2173
1926.404 F06
- Issued
- Oct 17, 2017
- Abate by
- Oct 27, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) On or about 5/11/2017, Basement area: Electrical equipment such as grinders and fans were in use with out continuous paths to ground. Abatement certification is required for this item.
Recent events (1)
- — Z (S) $0
1926.405 A02 II E
- Issued
- Oct 17, 2017
- Abate by
- Oct 27, 2017
- Penalty
- Initial $1,630 · Current $1,630
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(E): Lamps used in temporary wiring for general illumination were not protected from accidental contact or breakage: a) On or about 5/11/2017, Basement area: Temporary lighting bulbs were not provided with bulb covers. Abatement certification is required for this item.
Recent events (1)
- — Z (S) $1630
More inspections at Patricio Sanchez
View Patricio Sanchez's full OSHA safety record →
More inspections in this industry (NAICS 238120)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342379286.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.