BOHEMIA, NY —
OSHA Inspection: CONSTANCE FOOD GROUP INC. DBA NORRIS FOODS SERVICES
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CONSTANCE FOOD GROUP INC. DBA NORRIS FOODS SERVICES in 545 JOHNSON AVE., BOHEMIA, NY 11716 (NAICS 311919). OSHA activity number 342380870.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CONSTANCE FOOD GROUP INC. DBA NORRIS FOODS SERVICES
- Site address
- 545 JOHNSON AVE.
- City
- BOHEMIA
- State
- NY
- ZIP
- 11716
- Mailing
- 545 JOHNSON AVE., BOHEMIA, NY 11716
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311919
- Employees
- 310
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 I
- Issued
- Nov 21, 2017
- Abate by
- Dec 18, 2017
- Penalty
- Initial $12,675 · Current $12,675
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Worksite: Employees expected to perform cleaning, repair, and maintenance work on Great Lakes Meat Slicer, Model 1085SS, Serial No. 10545, powered by energy sources such as, but not limited to, electrical and pneumatic components, were neither provided with nor utilizing energy control procedures; on or about 5/30/17. b) Worksite: Employees expected to perform cleaning, repair, and maintenance work on Great Lakes Meat Slicer, Model 1085SS, Serial No. 10545, powered by energy sources such as, but not limited to, electrical and pneumatic components, were neither provided with nor utilizing energy control procedures; on or about 6/6/17. c) Worksite: Employees expected to perform cleaning, repair, and maintenance work on Great Lakes Meat Slicer, Model 1085SS, Serial No. 10544, powered by energy sources such as, but not limited to, electrical and pneumatic components, were neither provided with nor utilizing energy control procedures; on or about 6/6/17. d) Worksite: Employees expected to perform cleaning, repair, and maintenance work on Weber Slicing Line, Model CCS-402-627, Serial No. 376, powered by energy sources such as, but not limited to, electrical and pneumatic components, were neither provided with nor utilizing energy control procedures; on or about 6/6/17. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Recent events (1)
- — Z (S) $12675
1910.147 C07 I A
- Issued
- Nov 21, 2017
- Abate by
- Dec 18, 2017
- Penalty
- Initial $9,054 · Current $9,054
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation: a) Worksite: Employees authorized to perform cleaning, maintenance, and repair work on equipment powered by energy sources such as, but not limited to, electrical and pneumatic components, were not provided with adequate training on utilizing energy control procedures; on or about 6/6/17. Note: Abatement certification is required for this item in accordance with 29 CFR 1903.19.
Recent events (1)
- — Z (S) $9054
1910.147 C07 I B
- Issued
- Nov 21, 2017
- Abate by
- Dec 18, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure: a) Worksite: Employees working in proximity to equipment necessitating cleaning, maintenance, and repair work were not provided with training on the purpose and use of the energy control procedure; on or about 6/6/17. Note: Abatement certification is required for this item in accordance with 29 CFR 1903.19.