Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,194,531Inspections Most recent open 2026-08-11 Last loaded 2026-08-14

OSHA Inspection: AQUA EZ, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of AQUA EZ, INC. in 6100 WHEATON DR. SW, ATLANTA, GA 30336 (NAICS 325620). OSHA activity number 342381084.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Aqua EZ, INC. for free Get an email when a new federal OSHA severe-injury report for Aqua EZ, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
AQUA EZ, INC.
Site address
6100 WHEATON DR. SW
City
ATLANTA
State
GA
ZIP
30336
Mailing
6100 WHEATON DR. SW, ATLANTA, GA 30336
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325620
Employees
60
Ownership type
Private (A)

3 citations on file for this inspection.

1910.147 C01

Serious Gravity 10 2 instances 2 exposed
Issued
Aug 7, 2017
Abate by
Aug 31, 2017
Penalty
Initial $8,873 · Current $5,324 Reduced
29 CFR 1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.  a.  Throughout the plant - On or about June 8, 2017, employees were exposed to caught-in and burn hazards, in that an energy control program had not been established, consisting of written energy control procedures, training and inspections on equipment such as the mixers.
Recent events (2)
  • · I (S) $5323.8
  • · Z (S) $8873

1910.178 L01 I

Serious Gravity 5 2 instances 2 exposed
Issued
Aug 7, 2017
Abate by
Aug 31, 2017
Penalty
Initial $6,338 · Current $3,803 Reduced
29 CFR 1910.178(l)(1)(i): The employer shall ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l).  a.  Work area - On or about June 8, 2017, the employer exposed employees to struck-by hazards, in that training and certification was not completed for employees operating powered industrial trucks.
Recent events (2)
  • · I (S) $3802.8
  • · Z (S) $6338

1910.303 F02

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 7, 2017
Abate by
Aug 31, 2017
Penalty
Initial $6,338 · Current $3,803 Reduced
29 CFR 1910.303(f)(2): Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, shall be legibly marked to indicate its purpose, unless located and arranged so the purpose is evident.  a.  Tank area - On or about June 8, 2017, employees were exposed to struck-by and entanglement hazards in that the branch circuits in the panel board were not labeled or marked to indicate their purpose.
Recent events (2)
  • · I (S) $3802.8
  • · Z (S) $6338

View Aqua EZ, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342381084.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.