OSHA Inspection: RELIANCE TRUCK & EQUIPMENT LTD

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RELIANCE TRUCK & EQUIPMENT LTD in 7200 S WW WHITE RD, SAN ANTONIO, TX 78222 (NAICS 332313). OSHA activity number 342382595.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Reliance Truck & Equipment LTD for free Get an email when a new federal OSHA severe-injury report for Reliance Truck & Equipment LTD is published. One employer, no account, unsubscribe in one click.
Site address
7200 S WW WHITE RD
City
SAN ANTONIO
State
TX
ZIP
78222
Mailing
7200 S WW WHITE RD, SAN ANTONIO, TX 78222
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332313
Employees
6
Ownership type
Private (A)

6 citations on file for this inspection.

1910.178 P01

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 15, 2017
Penalty
Initial $2,173 · Current $978 Reduced
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition:    On or about June 8, 2017, and at times prior thereto, employees were exposed to ejection hazards while operating a Hyster forklift that had the manufacturer's installed seat belt removed.
Recent events (2)
  • · I (S) $978
  • · Z (S) $2173

1910.212 A01

Serious Gravity 5 2 instances 4 exposed
Issued
Nov 15, 2017
Penalty
Initial $2,173 · Current $978 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a) Shop Floor: On or about June 8, 2017, and at times prior thereto, employees were exposed to struck-by hazards while using a Northern Industrial Drill Press without a chuck guard installed.     b) Outside: On or about June 8, 2017, and at times prior thereto, employees were exposed to caught-in hazards while using an air compressor without the belt guard installed.
Recent events (2)
  • · I (S) $978
  • · Z (S) $2173

1910.215 B09

Serious Gravity 1 1 instance 4 exposed
Issued
Nov 15, 2017
Penalty
Initial $1,630 · Current $734 Reduced
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:    On or about June 8, 2017, and at times prior thereto, employees were exposed to struck-by hazards while using a Ryobi 3600 RPM bench grinder when the tongue guard was not adjusted to one fourth inch or less.
Recent events (2)
  • · I (S) $734
  • · Z (S) $1630

1910.305 B01 II

Serious Gravity 1 1 instance 4 exposed
Issued
Nov 15, 2017
Penalty
Initial $1,630 · Current $734 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    Maintenance area:  On or about June 8, 2017, and at times prior thereto, employees were exposed to electrical hazards, while accessing an electrical cabinet with a missing deadfront cover exposing live parts.
Recent events (2)
  • · I (S) $734
  • · Z (S) $1630

1910.334 A02 II

Serious Gravity 1 1 instance 4 exposed
Issued
Nov 15, 2017
Penalty
Initial $1,630 · Current $734 Reduced
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service and an employee was using it before repairs and tests necessary to render the equipment safe were made:    Maintenance area:  On or about June 8, 2017, and at times prior thereto, employees were exposed to electrical hazards, while using an extension cord with damaged areas to its outer insulation.
Recent events (2)
  • · I (S) $734
  • · Z (S) $1630

1910.157 C01

Other-than-serious 1 instance 4 exposed
Issued
Nov 15, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:   Maintenance Shop: On or about June 8, 2017, and at times prior thereto, employees were exposed to fire hazards, while the fire extinguisher was blocked from immediate access by a parts washer.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342382595.