Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: GNC CONCRETE PRODUCTS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of GNC CONCRETE PRODUCTS, INC. in 2100 N. 161ST E. AVE, TULSA, OK 74116 (NAICS 327390). OSHA activity number 342385010.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch GNC Concrete Products, INC. — free Get an email when a new federal OSHA severe-injury report for GNC Concrete Products, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2100 N. 161ST E. AVE
City
TULSA
State
OK
ZIP
74116
Mailing
P.O. BOX 2010, CATOOSA, OK 74015
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327390
Employees
50
Ownership type
A

5 citations on file for this inspection.

1910.28 B01 I

Serious Gravity 1 2 instances 10 exposed
Issued
Aug 10, 2017
Abate by
Sep 25, 2017
Penalty
Initial $3,802 · Current $2,281 Reduced
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following:  Guardrail systems, safety net systems, or personal fall arrest systems:    On or about June 7, 2017, and at times prior thereto, in the Manhole Department and Pipe Department floor openings approximately 4.5 feet high was not properly guarded by standard railings.  Employees were exposed to  fall hazards.
Recent events (2)
  • — I (S) $2281.2
  • — Z (S) $3802

1910.212 A01

Serious Gravity 5 3 instances 3 exposed
Issued
Aug 10, 2017
Abate by
Sep 25, 2017
Penalty
Initial $6,338 · Current $3,803 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:     On or about June 7, 2017, and at times prior thereto, employees were allowed to operate machines that were found not having guards provided, including but not limited to the following instances:     1) In the cutting/bending department, an iron worker machine was found not having guards provided.     2) In the cutting/bending department, a rebar cutting machine operated via foot pedal was not provided with a guard to cover the blade.     3) At the wet cast area, a roller being operated was not provided with tripwires or bars to shut the roller off in case of emergency.     Employees were exposed to possible amputation and crushing hazards.
Recent events (2)
  • — I (S) $3802.8
  • — Z (S) $6338

1910.219 D01

Serious Gravity 5 1 instance 5 exposed
Issued
Aug 10, 2017
Abate by
Aug 18, 2017
Penalty
Initial $5,070 · Current $3,042 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):    On or about June 7, 2017, and at times prior thereto, in the Pipe department a mixer motor driven by a belt and pulley approximately 2 foot from the floor level  and was not enclosed or guarded.  Employees were exposed to  amputation hazards.
Recent events (2)
  • — I (S) $3042
  • — Z (S) $5070

1910.303 G02 I

Serious Gravity 5 1 instance 5 exposed
Issued
Aug 10, 2017
Abate by
Aug 18, 2017
Penalty
Initial $6,338 · Current $3,803 Reduced
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating  at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i):    On or about June 7, 2017, and at times prior thereto, at the mixer area in Manhole Department a 240-Volt electrical panel with live electrical parts exposed was not guarded against accidental contact.  The employees were exposed to electric shock.
Recent events (2)
  • — I (S) $3802.8
  • — Z (S) $6338

1910.147 C01

Other-than-serious 1 instance 1 exposed
Issued
Aug 10, 2017
Abate by
Sep 25, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    On or about June 7, 2017, and at times prior thereto, at the establishment the employer did not establish a Lockout/Tag-out program consisting of an energy control procedure, employee training and periodic inspections in maintenance testing operations.  Employees were exposed to unexpected release of energy hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342385010.