On , OSHA opened a planned health inspection of ADVANCED INTEGRATED TECHNOLOGIES LLC in 200 LIGON STREET, NORFOLK, VA 23523 (NAICS 336611). OSHA activity number 342386166.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Advanced Integrated Technologies LLC — free Get an email when a new federal OSHA severe-injury report for Advanced Integrated Technologies LLC is published. One employer, no account, unsubscribe in one click.
Site address
200 LIGON STREET
City
NORFOLK
State
VA
ZIP
23523
Mailing
2427 INGLESIDE RD, NORFOLK, VA 23513
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336611
Employees
50
Ownership type
A

2 citations on file for this inspection.

1910.95 C01

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Aug 24, 2017
Abate by
Oct 12, 2017
Penalty
Initial $6,338 · Current $0 Reduced

Hazardous substances 81108111

29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.95(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent:  200 Ligon St., Norfolk, VA 23523, U.S.S. Gonzalez: On or about June 28, 2017, and times prior thereto, employees were exposed to noise levels in excess of the allowable 8-hour time weighted average (TWA) of 85dBA. This violation was observed on or about June 28, 2017,  a) Where noise sampling performed up to 228 minutes indicated that an employee was exposed up to an approximately 1193.8 percent noise dose which is equivalent to 107.9 dBA, exposing the employee to potential hearing loss. Zero exposure was assumed for the 252 minutes not sampled.  b) Where noise sampling performed up to 227 minutes indicated that an employee was exposed up to an approximately 512 percent noise dose which is equivalent to 101.8 dBA, exposing the employee to potential hearing loss. Zero exposure was assumed for the 253 minutes not sampled.  c) Where noise sampling performed up to 225 minutes indicated that an employee was exposed up to an approximately 653.8 percent noise dose which is equivalent to 103.5 dBA, exposing the employee to potential hearing loss. Zero exposure was assumed for the 255 minutes not sampled.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6338

1915.1026 D03

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Aug 24, 2017
Abate by
Oct 12, 2017
Penalty
Initial $5,070 · Current $0 Reduced

Hazardous substances 06890691

29 CFR 1915.1026(d)(3): The employer used the performance-oriented option; however, the employer did not determine the 8-hour time-weighted average exposure for each employee on the basis of any combination of air monitoring data, historical monitoring data, or objective data sufficient to accurately characterize employee exposure to chromium (VI):  200 Ligon St., Norfolk, VA 23523, U.S.S. Gonzalez: On or about June 12, 2017, and times prior thereto, the employer did not determine exposure for an employee that used a Thermcorp 85 Plasma Cutter and was exposed to hexavalent chromium in excess of the allowable 8-hour time weighted average (TWA) of 5 microgram/m3. This condition was observed on or about June 12, 2017, where personal air sampling performed up to 158 minutes indicated that the employee was exposed up to approximately 15.3 times the OSHA Permissible Exposure Limit, exposing the employee to potential health hazards including sensitization or asthma, skin sensitization or allergic contact dermatitis, and eye irritation. Zero exposure was assumed for the 322 minutes not sampled.  Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.