Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: J & E STRUCTURES, LLC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of J & E STRUCTURES, LLC. in JEFFERSON SQUARE APARTMENTS 726 WASHINGTON BOULEVARD, WILLIAMSPORT, PA 17701 (NAICS 999999). OSHA activity number 342387495.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J & E Structures, LLC. — free Get an email when a new federal OSHA severe-injury report for J & E Structures, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
JEFFERSON SQUARE APARTMENTS 726 WASHINGTON BOULEVARD
City
WILLIAMSPORT
State
PA
ZIP
17701
Mailing
196 HOY ROAD, HOWARD, PA 16841
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
999999
Employees
3
Ownership type
A

2 citations on file for this inspection.

1926.501 B11

Other-than-serious 1 instance 3 exposed
Issued
Jun 15, 2017
Penalty
Initial $3,803 · Current $0 Reduced
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems:        a) At the jobsite:  Employees were tearing down and replacing roof shingles from about 22 feet and 6 inches high from ground level on a 6 in 12 pitch roof without the use of appropriate fall protection. Employees were exposed to fall hazards as observed on or about June 7, 2017.                                                                CORRECTED DURING INSPECTION.
Recent events (3)
  • — F (O) $0
  • — C (S) $3803
  • — Z (S) $3803

1926.453 B02 V

Other-than-serious 1 instance 3 exposed
Issued
Jun 15, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift: Note:  As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system.  The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated:          a) At the jobsite:  Employee were working inside the platform of the Genie Z-60/34 boom lift about 22 feet high from ground level without appropriate fall protection, as observed on or about June 7, 2017.                                                                                CORRECTED DURING INSPECTION
Recent events (3)
  • — F (O) $0
  • — C (S) $0
  • — Z (S) $0

View J & E Structures, LLC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342387495.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.