NEW YORK, NY ·
OSHA Inspection: 98 CONSTRUCTION INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of 98 CONSTRUCTION INC. in 70 EAST BROADWAY, NEW YORK, NY 10002 (NAICS 238190). OSHA activity number 342389368.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- 98 CONSTRUCTION INC.
- Site address
- 70 EAST BROADWAY
- City
- NEW YORK
- State
- NY
- ZIP
- 10002
- Mailing
- 44 MONROE STREET, NEW YORK, NY 10002
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238190
- Employees
- 5
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.59
- Issued
- Oct 12, 2017
- Abate by
- Oct 23, 2017
- Penalty
- Initial $1,630 · Current $1,630
General-duty citation text
29 CFR 1926.59: 29 CFR 1926.59: An employer engaged in construction activities did not comply with the requirements set forth in Part 1910, Section 1200, Hazard Communication: a) At the jobsite, on or about 6/6/17: Employees were working with chemicals without having been HAZCOM trained and without having SDS's available upon request.
Recent events (1)
- · Z (S) $1630
1926.403 B01 I
- Issued
- Oct 12, 2017
- Abate by
- Oct 23, 2017
- Penalty
- Initial $2,716 · Current $2,716
General-duty citation text
29 CFR 1926.403(b)(1)(i): Safety of equipment was not determined on the basis of suitability of the equipment for an identified purpose as evidenced by listing, labeling, or certification for that identified purpose. a) At the jobsite, on or about 6/6/17: Inside the elevator, a quad outlet box was hanging from the power cord, secured with tape, and not secured to a solid surface.
Recent events (1)
- · Z (S) $2716
1926.403 I02 I
- Issued
- Oct 12, 2017
- Abate by
- Oct 18, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph: a) At the jobsite, on or about 6/6/17: In the basement, inside the service panel, no cover was in place exposing workers to contact live electrical circuits. b) At the jobsite, on or about 6/6/17: In the stairwell, multiple lighting fixtures hung by their wires, with contacts exposed and with open junction boxes, exposing workers to contact with live electrical circuits.
Recent events (1)
- · Z (S) $3803
1926.404 B01 I
- Issued
- Oct 12, 2017
- Abate by
- Oct 18, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: a) At the jobsite, on or about 6/6/17: Workers use a variety of power tools and supplied electrical power throughout the building without GFI protection.
Recent events (1)
- · Z (S) $3803
1926.1053 B01
- Issued
- Oct 12, 2017
- Abate by
- Oct 23, 2017
- Penalty
- Initial $2,716 · Current $2,716
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) At the jobsite, on or about 6/6/17: Inside the elevator shaft pit, employees used a 4 foot step ladder placed against the wall of the pit to enter and exit, where the top level of the ladder was flush with the upper floor surface and did not extend at least 3 feet above this landing.
Recent events (1)
- · Z (S) $2716
1926.1053 B04
- Issued
- Oct 12, 2017
- Abate by
- Oct 23, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:(a) a) At the jobsite, on or about 6/6/17: Inside the elevator shaft pit, employees used a 4 foot step ladder placed against the wall of the pit to enter and exit, and not opened with the spreaders locked as it is designed to be used.
Recent events (1)
- · Z (S) $0
1926.1053 B13
- Issued
- Oct 12, 2017
- Abate by
- Oct 23, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step: a) At the jobsite, on or about 6/6/17: Inside the elevator shaft pit, employees used a 4 foot step ladder placed against the wall of the pit to enter and exit, requiring to step onto and off of the top of the ladder.
Recent events (1)
- · Z (S) $0
More inspections at 98 Construction INC.
View 98 Construction INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238190)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342389368.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.