SARASOTA, FL —
OSHA Inspection: HARMAR MOBILITY, LLC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of HARMAR MOBILITY, LLC. in 2075 47TH STREET, SARASOTA, FL 34234 (NAICS 332999). OSHA activity number 342389590.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HARMAR MOBILITY, LLC.
- Site address
- 2075 47TH STREET
- City
- SARASOTA
- State
- FL
- ZIP
- 34234
- Mailing
- 2075 47TH STREET, SARASOTA, FL 34234
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 105
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.134 C01
- Issued
- Nov 7, 2017
- Abate by
- Dec 27, 2017
- Penalty
- Initial $6,519 · Current $6,519
0689
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: (a) As observed on or about 06/26/2017, for employees welding stainless steel parts for the manufacturing of pool lifts exposed to hexavalent chromium without the use of respiratory protection.
Recent events (1)
- — Z (S) $6519
1910.1026 C
- Issued
- Nov 7, 2017
- Abate by
- Dec 13, 2017
- Penalty
- Initial $0 · Current $0
0689
General-duty citation text
29 CFR 1910.1026(c): Employees were exposed to an airborne concentration of chromium (VI) which exceeded 5 micrograms per cubic meter of air, as an 8-hour time-weighted average: (a) As observed on or about 06/26/2017, an employee welding stainless steel parts for the manufacturing of pool lifts was exposed to hexavalent chromium at a TWA level of 0.00722 milligrams per cubic meter. The exposure level was derived from three samples collected over a 430-minute period.
Recent events (1)
- — Z (S) $0
1910.1026 D01
- Issued
- Nov 7, 2017
- Abate by
- Dec 27, 2017
- Penalty
- Initial $0 · Current $0
0689
General-duty citation text
29 CFR 1910.1026(d)(1): The employer with a workplace or work operation covered by this standard did not determine the 8-hour time-weighted average exposure for each employee exposed to chromium (VI): (a) As observed on or about 06/26/17, for employees welding stainless steel parts for the manufacturing of pool lifts where one employee was exposed to 0.00722 milligrams per cubic meter of hexavalent chromium.
Recent events (1)
- — Z (S) $0
1910.1026 G01 IV
- Issued
- Nov 7, 2017
- Abate by
- Dec 27, 2017
- Penalty
- Initial $0 · Current $0
0689
General-duty citation text
29 CFR 1910.1026(g)(1)(iv): The employer did not provide each employee an appropriate respirator during work operations where the employer had not implemented feasible engineering and work practice controls to achieve the permissible exposure limit for employees who were exposed above the permissible exposure limit for fewer than 30 days per year: (a) As observed on or about 06/26/2017, for employees welding stainless steel parts for the manufacturing of pool lifts exposed to hexavalent chromium without the use of respiratory protection.
Recent events (1)
- — Z (S) $0
1910.252 A02 VII
- Issued
- Nov 7, 2017
- Abate by
- Nov 20, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.252(a)(2)(vii): Where practicable, combustible materials were not relocated at least 35 feet (10.7 m) from the cutting or welding operation work site: (a) For employees at the Welding Department, as observed on or about 06/07/2017: (1) at the MIG manual welding stations, in that, table partitions were made of plywood sheets, (2) at a MIG manual welding stations, in that, welding was performed on top of a stack of wooden pallets, and (3) at the robot welding station, in that, metal parts were kept in cardboard boxes on top of the welding tables.
Recent events (1)
- — Z (O) $0
1910.252 A02 IX
- Issued
- Nov 7, 2017
- Abate by
- Nov 20, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.252(a)(2)(ix): Where cutting or welding was done near walls, partitions, ceiling or roof of combustible construction, fire-resistant shields or guards were not provided to prevent ignition: (a) For employees at the Welding Department, as observed on or about 06/07/2017 at the MIG manual welding stations, in that, table partitions were made of plywood sheets.
Recent events (1)
- — Z (O) $0
1910.305 G01 IV A
- Issued
- Nov 7, 2017
- Abate by
- Nov 20, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: (a) As observed on or about 06/07/2017, for employees at layout table #1 in the Helix Department, in that, a relocatable power tap (multi-plug extension cord) tied to the table was connected to an extension cord and was used for powering equipment such as, but not limited to, grinders and pedestal fans.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 332999)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342389590.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.