RICHMOND, TX —
OSHA Inspection: STILLO CONSTRUCTION, LLC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of STILLO CONSTRUCTION, LLC. in 308 MORTON ST., RICHMOND, TX 77469 (NAICS 238310). OSHA activity number 342391240.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STILLO CONSTRUCTION, LLC.
- Site address
- 308 MORTON ST.
- City
- RICHMOND
- State
- TX
- ZIP
- 77469
- Mailing
- 3452 BACOR RD, HOUSTON, TX 77084
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238310
- Employees
- 6
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 F03
- Issued
- Sep 13, 2017
- Abate by
- Oct 2, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(3): Scaffold and scaffold components were not inspected for visible defects by a competent person before each workshift and after any occurrence which could affect a scaffold's structural integrity: a) At the job site the fabricated frame scaffold was not inspected by a competent person.
Recent events (1)
- — Z (O) $0
1926.451 C01
- Issued
- Sep 13, 2017
- Abate by
- Oct 2, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by guying, tying, bracing, or equivalent means, as set forth in subparagraphs (i) - (iii) of this paragraph: a) At the jobsite the fabricated frame scaffold with dimensions (3ft width x 29ft height) was not tied to the building.
Recent events (1)
- — Z (O) $0
1926.451 C02 I
- Issued
- Sep 13, 2017
- Abate by
- Oct 2, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement: a) At the job site the fabricated frame scaffold did not had the base plates secured or nailed to the mudsills to prevent accidental displacement.
Recent events (1)
- — Z (O) $0
1926.451 G04 III
- Issued
- Sep 13, 2017
- Abate by
- Oct 2, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(4)(iii): Midrails were not installed midway between the top rail and the platform surface: a) At the jobsite the fabricated frame scaffold was missing the midrails on the second and third deck.
Recent events (1)
- — Z (O) $0
More inspections at Stillo Construction, LLC.
View Stillo Construction, LLC.'s full OSHA safety record →
More inspections in this industry (NAICS 238310)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342391240.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.