OSHA Inspection: S.G. YOUNG CONTRACTING, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of S.G. YOUNG CONTRACTING, LLC in 111 HYLTON LANE, BECKLEY, WV 25801 (NAICS 238160). OSHA activity number 342392131.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch S.G. Young Contracting, LLC — free Get an email when a new federal OSHA severe-injury report for S.G. Young Contracting, LLC is published. One employer, no account, unsubscribe in one click.
Site address
111 HYLTON LANE
City
BECKLEY
State
WV
ZIP
25801
Mailing
107 E. FUDGE STREET, COVINGTON, VA 24426
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
7
Ownership type
A

6 citations on file for this inspection.

1926.501 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 28, 2017
Abate by
Sep 6, 2017
Penalty
Initial $2,716 · Current $1,630 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.    (a) Outback Steakhouse:  On or about June 6, 2017 and times prior, two employees were working on securing a section of metal roofing to the edge of the roof while standing and walking inside the 1ft. parapet wall of the newly constructed entrance tower on the roof up to 14ft. 7in. above grade without the use of a fall protection system.
Recent events (2)
  • — I (S) $1629.6
  • — Z (S) $2716

1926.403 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 28, 2017
Abate by
Sep 8, 2017
Penalty
Initial $2,716 · Current $1,630 Reduced
29 CFR 1926.403(b)(1): Employer did not ensure that electrical equipment is free from recognized hazards that are likely to cause death or serious physical harm to employees.      (a) Outback Steakhouse:  On or about June 6, 2017 and times prior, employees were using a 120 volt Leister Triac S hot air welder gun to weld the ends of the rubber membrane being applied to the roof.  The power cord was damaged exposing the insulated conductors to damage.
Recent events (2)
  • — I (S) $1629.6
  • — Z (S) $2716

1926.20 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 28, 2017
Abate by
Sep 8, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s).  (a) Outback Steakhouse:  On or about June 6, 2017 and times prior, inspections and/or audits of the worksite were not required or performed by the employer to identify and correct hazards presented, such as employees using powered equipment with defective power cords.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.404 F06

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 28, 2017
Abate by
Sep 6, 2017
Penalty
Initial $2,716 · Current $1,630 Reduced
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous.    (a) Outback Steakhouse:  On or about June 6, 2017 and times prior, a 12AWG 50 foot Ridgid extension cord, with a missing ground pin was used by employees to supply power to a 120 volt Leister hot air gun.
Recent events (2)
  • — I (S) $1629.6
  • — Z (S) $2716

1926.405 G02 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 28, 2017
Abate by
Sep 6, 2017
Penalty
Initial $2,716 · Current $1,630 Reduced
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws.      (a) Outback Steakhouse:  On or about June 6, 2017 and times prior, a 12AWG 50 foot Ridgid extension cord to power a hand held Leister hot air gun that had the outer protective coating pulled away from the female plug end exposing insulated conductors to damage.
Recent events (2)
  • — I (S) $1629.6
  • — Z (S) $2716

1926.404 B01 III C

Serious Gravity 5 1 instance 2 exposed
Issued
Aug 28, 2017
Abate by
Sep 6, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.404(b)(1)(iii)(C): The employer did not ensure that each cord set, attachment cap, plug and receptacle of cord sets, and any equipment connected by cord and plug, except cord sets and receptacles which are fixed and not exposed to damage, were visually inspected before each day's use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage.  (a) Outback Steakhouse:  On or about June 6, 2017 and times prior, a 12AWG 50 foot Ridgid extension cord to power a hand held Leister hot air gun was not inspected for defects prior to employee use.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View S.G. Young Contracting, LLC's full OSHA safety record →