JASPER, AL ·
OSHA Inspection: CARL CANNON, INC.
Fatality or catastrophe inspection · Safety discipline
At a glance
On , OSHA opened a fatality or catastrophe safety inspection of CARL CANNON, INC. in 299 CARL CANNON BOULEVARD, JASPER, AL 35501 (NAICS 441110). OSHA activity number 342395373.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CARL CANNON, INC.
- Site address
- 299 CARL CANNON BOULEVARD
- City
- JASPER
- State
- AL
- ZIP
- 35501
- Mailing
- 299 CARL CANNON BOULEVARD, JASPER, AL 35501
What kind of inspection was it?
- Inspection type
- Fatality or catastrophe (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 441110
- Employees
- 60
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.106 D05 VI B
- Issued
- Dec 7, 2017
- Abate by
- Aug 11, 2018
- Penalty
- Initial $12,675 · Current $12,675
General-duty citation text
29 CFR 1910.106(d)(5)(vi)(b): The storage of flammable liquid inside a building did not comply with Table H-14, in that flammable liquid was stored in a basement location: (a) On or about 6/12/2017 - Express Lube Pit, FLYNN ACP200 Brake Wash, a Category 2 flammable liquid, was stored in a 30 gallon metal drum in a below ground vehicle service pit.
Recent events (3)
- · J (S) $12675
- · C (S) $12675
- · Z (S) $12675
1910.307 C
- Issued
- Dec 7, 2017
- Abate by
- Aug 11, 2018
- Penalty
- Initial $12,675 · Current $12,675
General-duty citation text
29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location: (a) On or about 6/12/2017 - Express Lube Pit, electrical receptacles, a pedestal fan, and a Hessaire Portable Evaporative Cooler, Model MC37, were not intrinsically safe for use in a Class I, Division 1 location created as a result of employees using flammable brake wash liquid to clean oil and grease from the service pit floor, thereby exposing employees to a flash fire and explosion hazard from the aforementioned ignition sources.
Recent events (3)
- · J (S) $12675
- · C (S) $12675
- · Z (S) $12675
1910.1200 E01
- Issued
- Dec 7, 2017
- Abate by
- Aug 11, 2018
- Penalty
- Initial $126,749 · Current $88,724 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): (a) On or about 6/12/2017 - Carl Cannon, Inc. dealership management did not implement the written Hazard Communication program (HCP), purchased from Compliance Specialists, Inc. (CSI) in October 2012, which described how program requirements such as chemical labeling, safety data sheets, and training would be met.
Recent events (3)
- · J (W) $88724.25
- · C (W) $126749
- · Z (W) $126749
More inspections at Carl Cannon, INC.
View Carl Cannon, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 441110)
More inspections in AL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342395373.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.