MARYVILLE, IL ·
OSHA Inspection: LOBO ROOFING LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LOBO ROOFING LLC in 2120 TUSCANY RIDGE CT., MARYVILLE, IL 62062 (NAICS 238160). OSHA activity number 342395951.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LOBO ROOFING LLC
- Site address
- 2120 TUSCANY RIDGE CT.
- City
- MARYVILLE
- State
- IL
- ZIP
- 62062
- Mailing
- 3347 MODESTO LANE, SAINT ANN, MO 63074
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 8
- Ownership type
- A
Citations
8 citations on file for this inspection.
1926.20 B02
- Issued
- Jul 18, 2017
- Abate by
- Mar 2, 2018
- Penalty
- Initial $2,716 · Current $1,358 Reduced
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s): The employer did not maintain jobsite inspections that were performed by a person competent to ensure employees were not exposed to the hazard of falling and being struck by hazards during roofing operations.
Recent events (3)
- · F (S) $1358
- · C (S) $2716
- · Z (S) $2716
1926.102 A01
- Issued
- Jul 18, 2017
- Abate by
- Mar 2, 2018
- Penalty
- Initial $2,173 · Current $1,087 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: Eye protective equipment was not used when employees were exposed to eye injury while using pneumatic nail guns to perform roof installation operations.
Recent events (3)
- · F (S) $1086.5
- · C (S) $2173
- · Z (S) $2173
1926.152 D04
- Issued
- Jul 18, 2017
- Abate by
- Mar 2, 2018
- Penalty
- Initial $2,716 · Current $1,358 Reduced
General-duty citation text
29 CFR 1926.152(d)(4): At least one portable fire extinguisher having a rating of not less than 20B:C units was not provided on all vehicles used for transporting and/or dispensing flammable or combustible liquids: The employer did not ensure that a portable fire extinguisher was available to employees who were carrying a five (5) gallon gasoline can in the vehicle. The gasoline was being used to fill the air compressor.
Recent events (3)
- · F (S) $1358
- · C (S) $2716
- · Z (S) $2716
1926.501 B13
- Issued
- Jul 18, 2017
- Abate by
- Mar 2, 2018
- Penalty
- Initial $3,803 · Current $1,902 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: The employer did not ensure fall protection was implemented during residential construction operations when workers were exposed to the hazard of falling up to approximately twelve (12) feet off the roof eve when they were performing roofing operations.
Recent events (3)
- · F (S) $1901.5
- · C (S) $3803
- · Z (S) $3803
1926.502 D16 III
- Issued
- Jul 18, 2017
- Abate by
- Mar 2, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could not free fall more than 6 feet (1.8 m) nor contact any lower level: The employer did not ensure that fall protection systems were used in a manner to keep employees from free falling more than 6 foot while performing roofing activities.
Recent events (3)
- · F (S) $0
- · C (S) $0
- · Z (S) $0
1926.502 D06 I
- Issued
- Jul 18, 2017
- Abate by
- Mar 2, 2018
- Penalty
- Initial $3,803 · Current $1,902 Reduced
General-duty citation text
29 CFR 1926.502(d)(6)(i): A snaphook not of the locking type was engaged (i) directly to webbing, rope or wire rope; (ii) to each other (iii) to a Dee-ring to which another snaphook or other connector is attached;(iv) to a horizontal lifeline; or (v) to any objectwhich is incompatibly shaped or dimensioned in relation to the snaphook such that unintentional disengagement could occur by the connected object being able to depress the snaphook keeper and release itself. The employer did not ensure that a snaphook used on a personal fall arrest system was not connected to vertical lifeline rope.
Recent events (3)
- · F (S) $1901.5
- · C (S) $3803
- · Z (S) $3803
1926.502 D06 III
- Issued
- Jul 18, 2017
- Abate by
- Mar 2, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(d)(6)(iii): A snaphook not of the locking type was engaged (i) directly to webbing, rope or wire rope; (ii) to each other (iii) to a Dee-ring to which another snaphook or other connector is attached;(iv) to a horizontal lifeline; or (v) to any objectwhich is incompatibly shaped or dimensioned in relation to the snaphook such that unintentional disengagement could occur by the connected object being able to depress the snaphook keeper and release itself. The employer did not ensure that a snaphook used on a personal fall arrest system was not connected to an anchor Dee-ring which another snaphook was connected.
Recent events (3)
- · F (S) $0
- · C (S) $0
- · Z (S) $0
1926.502 D15
- Issued
- Jul 18, 2017
- Abate by
- Mar 2, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(d)(15): Anchorage points used for attachment of personal fall arrest equipment were not independent of any anchorage point being used to support or suspend platforms and capable of supporting at least 5,000 pounds (22.2 kN) per employee: The employer did not ensure fall protection anchor points were installed to support at least 5,000 pounds for employees who were exposed to the hazard of falling approximately twelve (12) feet while performing roofing activities.
Recent events (3)
- · F (S) $0
- · C (S) $0
- · Z (S) $0
More inspections at Lobo Roofing LLC
View Lobo Roofing LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342395951.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.