Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: AUTOMATIC SMP

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of AUTOMATIC SMP in 709 2ND AVENUE SE, DECATUR, AL 35601 (NAICS 332721). OSHA activity number 342399706.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Automatic SMP for free Get an email when a new federal OSHA severe-injury report for Automatic SMP is published. One employer, no account, unsubscribe in one click.
Establishment
AUTOMATIC SMP
Site address
709 2ND AVENUE SE
City
DECATUR
State
AL
ZIP
35601
Mailing
P.O. BOX 1608, DECATUR, AL 35602
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332721
Employees
105
Ownership type
Private (A)

6 citations on file for this inspection.

1910.22 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Jul 14, 2017
Abate by
Jul 24, 2017
Penalty
Initial $7,243 · Current $5,000 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, service rooms and walking-working surfaces were not kept clean, orderly and in sanitary condition.    a) On or about 06/14/2017 - Core department, the floor of the department was congested with boxes, pallets, and chairs while employees worked around machinery.
Recent events (2)
  • · I (S) $5000
  • · Z (S) $7243

1910.147 C04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jul 14, 2017
Abate by
Jul 26, 2017
Penalty
Initial $10,864 · Current $7,500 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    a) On or about 06/14/2017 - Core department, slotter machine, an employee clearing a jammed nut did not utilize the established specific procedure.
Recent events (2)
  • · I (S) $7500
  • · Z (S) $10864

1910.147 C07 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 14, 2017
Abate by
Jul 26, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:  a) On or about 06/14/2017 - Core department, slotter machine, employees performing maintenance activities did not have the knowledge, skills, and abilities to ensure their safety while performing tasks such as, but not limited to, changing the oil and replacing the cutting heads.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 5 exposed
Issued
Jul 14, 2017
Abate by
Jan 31, 2018
Penalty
Initial $10,864 · Current $7,500 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a) On or about 06/14/2017 - Core department, employees operate machinery such as, but not limited to, the Wenzler #416 slotter machine with unguarded rotating parts.     b) On or about 06/14/2017 - Core department, employees operate a vertical milling machine #426 with unguarded rotating parts.     c) On or about 06/14/2017 - Core department, employees operate machinery such as Powermatic reamers #311, #316, and #324 with unguarded rotating parts.     d) On or about 06/14/2017 - Core department, employees operate machinery such as Powermatic countersinks #312 and #317 with unguarded rotating parts.     e) On or about 06/14/2017 - Core department, employees operate a MSC band saw #653 with the unused portion of the rotating blade exposed.
Recent events (2)
  • · I (S) $7500
  • · Z (S) $10864

1910.215 A04

Serious Gravity 5 1 instance 4 exposed
Issued
Jul 14, 2017
Abate by
Jul 26, 2017
Penalty
Initial $7,243 · Current $5,000 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one-eighth inch:    a) On or about 06/14/2017 - Core department, employees operate a Dayton, 7 inch, #103 with two side grinders that were out of adjustment by 13/16th of an inch on the left side and the work rest on the right side was completely broken off.
Recent events (2)
  • · I (S) $5000
  • · Z (S) $7243

1910.147 C06 I

Other-than-serious 1 instance 4 exposed
Issued
Jul 14, 2017
Abate by
Jul 26, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a) On or about 06/14/2017 - Core department, specific procedures for equipment such as, but not limited to, the slotter machines had not been inspected since 2014.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 342399706.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.