OSHA Inspection: PETRA REPAIR & MAINTENANCE, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PETRA REPAIR & MAINTENANCE, LLC in 35 WALKER STREET, NEW YORK, NY 10013 (NAICS 238990). OSHA activity number 342405198.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Petra Repair & Maintenance, LLC — free Get an email when a new federal OSHA severe-injury report for Petra Repair & Maintenance, LLC is published. One employer, no account, unsubscribe in one click.
Site address
35 WALKER STREET
City
NEW YORK
State
NY
ZIP
10013
Mailing
36-24 32ND STREET, ASTORIA, NY 11106
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
10
Ownership type
A

9 citations on file for this inspection.

1926.303 B01

Serious Gravity 5 1 instance 10 exposed
Issued
Oct 12, 2017
Abate by
Oct 18, 2017
Penalty
Initial $2,173 · Current $2,173
29 CFR 1926.303(b)(1): Grinding machines were not equipped with safety guards in conformance with the requirements of ANSI B7.1-1970, Safety Code for the Use, Care, and Protection of abrasive wheels, and paragraph (d) of this section.  a)  At the jobsite, on or about 6/6/17:  Workers were using handheld grinders, with cutting wheels installed, and without guards.
Recent events (1)
  • — Z (S) $2173

1926.403 I02 I

Serious Gravity 10 2 instances 10 exposed
Issued
Oct 12, 2017
Abate by
Oct 18, 2017
Penalty
Initial $3,803 · Current $3,803
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph:   a)  At the jobsite, on or about 6/6/17:  In the basement, inside the service panel, no cover surrounded the breaker switches, exposing workers to contact live electrical circuits.    b)  At the jobsite, on or about 6/6/17:  In the basement, inside the service panel, no covers were placed over 3 open breaker positions.
Recent events (1)
  • — Z (S) $3803

1926.404 B01 I

Serious Gravity 10 1 instance 10 exposed
Issued
Oct 12, 2017
Abate by
Oct 18, 2017
Penalty
Initial $3,803 · Current $3,803
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites:  a)  At the jobsite, on or about 6/6/17:  In the basement, a 3 pronged 220 outlet was direct wired from the panel without GFCI protection.
Recent events (1)
  • — Z (S) $3803

1926.451 G01

Serious Gravity 10 1 instance 10 exposed
Issued
Oct 12, 2017
Abate by
Oct 18, 2017
Penalty
Initial $3,803 · Current $3,803
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:  a)  At the jobsite, on or about 6/6/17:  On the 5th floor (roof level), employees were working from a 3 foot scaffold that was placed directly next to a stairwell, exposing workers to falls of 13 feet to the lower level.
Recent events (1)
  • — Z (S) $3803

1926.502 D05

Serious Gravity 5 1 instance 10 exposed
Issued
Oct 12, 2017
Abate by
Oct 18, 2017
Penalty
Initial $2,716 · Current $2,716
29 CFR 1926.502(d)(5): Locking-type snaphooks were not designed and used to prevent disengagement of the snaphook by the contact of the snaphook keeper by the connected member:  a)  At the jobsite, on or about 6/6/17:  On the 5th floor (roof level), employees were working along the outer perimeter of the building, 5 stories from ground, and using personal fall arrest equipment where they passed the lifeline around a vertical member and attached the snaphook back onto its line.
Recent events (1)
  • — Z (S) $2716

1926.502 D11

Serious Gravity 5 1 instance 10 exposed
Issued
Oct 12, 2017
Abate by
Oct 18, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(11): Lifelines were not protected against being cut or abraded:  a)  At the jobsite, on or about 6/6/17:  On the 5th floor (roof level), employees were working along the outer perimeter of the building, 5 stories from ground, and using personal fall arrest equipment where they tied a lifeline into steel studs, exposing the line to being cut.
Recent events (1)
  • — Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 10 exposed
Issued
Oct 12, 2017
Abate by
Oct 18, 2017
Penalty
Initial $2,173 · Current $2,173
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed  a)  At the jobsite, on or about 6/6/17:  On the 5th floor (roof level), employees were using a 6 foot step ladder that did not extend at least 3 feet above the upper landing.
Recent events (1)
  • — Z (S) $2173

1926.1053 B04

Serious Gravity 5 1 instance 10 exposed
Issued
Oct 12, 2017
Abate by
Oct 18, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purposes for which they were designed:(a)(LOCATION)(IDENTIFY SPECIFIC OPERATIONS(S) AND/OR CONDITIONS)  a)  At the jobsite, on or about 6/6/17:  On the 5th floor (roof level), employees were using a 6 foot step ladder that was placed against the wall, without being opened and without the spreaders locked, as it is designed to be used.
Recent events (1)
  • — Z (S) $0

1926.1053 B13

Serious Gravity 5 1 instance 10 exposed
Issued
Oct 12, 2017
Abate by
Oct 18, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step:  a)  At the jobsite, on or about 6/6/17:  On the 5th floor (roof level), employees were using a 6 foot step ladder that was placed against the wall where it required users to use the top of the ladder to access the upper landing.