Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GLEASON REEL CORP.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GLEASON REEL CORP. in 600 S. CLARK STREET, MAYVILLE, WI 53050 (NAICS 334513). OSHA activity number 342406683.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Gleason Reel Corp. — free Get an email when a new federal OSHA severe-injury report for Gleason Reel Corp. is published. One employer, no account, unsubscribe in one click.
Establishment
GLEASON REEL CORP.
Site address
600 S. CLARK STREET
City
MAYVILLE
State
WI
ZIP
53050
Mailing
P. O. BOX 26, MAYVILLE, WI 53050
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
334513
Employees
172
Ownership type
A

2 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 26, 2017
Abate by
Nov 7, 2017
Penalty
Initial $7,696 · Current $7,696
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    (a)  Procedures were not developed to protect employees from an electrical hazard while testing the control box on transformers for Baltimore Power.   Proper procedures would include where employees should stand while testing equipment, insurance that the transformer is properly wired, and all doors are closed to minimize exposure to any electrical hazard.
Recent events (2)
  • — I (S) $7696
  • — Z (S) $7696

1910.333 A

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 26, 2017
Abate by
Nov 7, 2017
Penalty
Initial $7,696 · Current $0 Reduced
29 CFR 1910.333(a): Safety-related work practices were not employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work was performed near or on equipment or circuits which were or could be energized:    (a)  The employer did not develop electrical safe work practices for employees working on transformers to prevent electric shock or other injuries.  On or about June 19, 2017 an employee received an electrical shock while working inside of a transformer.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7696

View Gleason Reel Corp.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342406683.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.