BOISE, ID —
OSHA Inspection: IDAHO TIMBER OF BOISE, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of IDAHO TIMBER OF BOISE, LLC in 4800 PRODUCTION AVE, BOISE, ID 83705 (NAICS 321113). OSHA activity number 342409034.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- IDAHO TIMBER OF BOISE, LLC
- Site address
- 4800 PRODUCTION AVE
- City
- BOISE
- State
- ID
- ZIP
- 83705
- Mailing
- 4800 PRODUCTION AVE, BOISE, ID 83705
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321113
- Employees
- 45
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.132 A
- Issued
- Aug 1, 2017
- Abate by
- Sep 18, 2017
- Penalty
- Initial $12,675 · Current $11,500 Reduced
General-duty citation text
29 CFR 1910.132(a): Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact. a) On or about June 8, 2017 or prior thereto: Testing procedures were conducted on a Quincy Air Compressor Model #QNW-IQ-F50T/S, Serial #000556, and the employer did not utilize Personal Protective equipment to protect employees from hazards encountered by connecting open splices on a 480V circuit. NOTE: Abatement certification and documentation are required for this item.
Recent events (2)
- — I (S) $11500
- — Z (S) $12675
1910.132 D01
- Issued
- Aug 1, 2017
- Abate by
- Sep 18, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE). a) On or about June 8, 2017 or prior thereto: Testing procedures were conducted on a Quincy Air Compressor Model #QNW-IQ-F50T/S, Serial #000556, and the employer did not assess what personal protective equipment was necessary to protect employees from hazards encountered by open splices on a 480V circuit. Electrical PPE was not worn by employees during this operation. NOTE: Abatement certification and documentation are required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.133 A01
- Issued
- Aug 1, 2017
- Abate by
- Sep 18, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation. a) On or about June 8, 2017 or prior thereto: Testing procedures were conducted on a Quincy Air Compressor Model #QNW-IQ-F50T/S, Serial #000556, and the employer did not utilized eye and face protection necessary to protect employees from hazards encountered by open splices on a 480V circuit. NOTE: Abatement certification and documentation are required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.138 A
- Issued
- Aug 1, 2017
- Abate by
- Sep 18, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.138(a): Employers did not select and require employees to use appropriate hand protection when employees' hands are exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasions; punctures; chemical burns; thermal burns; and harmful temperature extremes. a) On or about June 8, 2017 or prior thereto: Testing procedures were conducted on a Quincy Air Compressor Model #QNW-IQ-F50T/S, Serial #000556, and the employer did not utilize gloves to protect from hazards encountered by connecting open splices on a 480V circuit or during testing procedures. NOTE: Abatement certification and documentation are required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.333 C02
- Issued
- Aug 1, 2017
- Abate by
- Sep 18, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.333(c)(2): Qualified persons did not work on electric circuit parts or equipment that have not been deenergized under the procedures of paragraph (b) of this section. Persons working on equipment were not be capable of working safely on energized circuits and were not familiar with the proper use of special precautionary techniques, personal protective equipment, insulating and shielding materials, and insulated tools. a) On or about June 8, 2017 or prior thereto: Qualified persons did not perform testing procedures on a Quincy Air Compressor Model #QNW-IQ-F50T/S, Serial #000556, and employees were not protected from hazards encountered by connecting open splices on a 480V circuit. NOTE: Abatement certification and documentation are required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B01 VIII
- Issued
- Aug 1, 2017
- Abate by
- Sep 18, 2017
- Penalty
- Initial $9,959 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(b)(1)(viii): Electric equipment was not free from recognized hazards that are likely to cause death or serious physical harm to employees. Safety of equipment was not be determined including other factors that contribute to the practical safeguarding of persons using or likely to come in contact with the equipment. a) On or about June 8, 2017 or prior thereto: Testing procedures were conducted on a Quincy Air Compressor Model #QNW-IQ-F50T/S, Serial #000556, and the employer did follow instructions in the Quincy Operator's Manual for operation of the compressor. This includes having a Safety Device such as a High Temperature Safety Switch installed between the compressor discharge and air receiver, and ensuring that the control circuit must be fused as required by the National Electrical Code. NOTE: Abatement certification is required for this item.
Recent events (2)
- — I (S) $0
- — Z (S) $9959
More inspections at Idaho Timber of Boise, LLC
View Idaho Timber of Boise, LLC's full OSHA safety record →
More inspections in this industry (NAICS 321113)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342409034.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.