CORPUS CHRISTI, TX —
OSHA Inspection: SOUTH TEXAS MOULDING, INC.
Follow-up inspection · Safety discipline
At a glance
On , OSHA opened a follow-up safety inspection of SOUTH TEXAS MOULDING, INC. in 6525 AYERS STREET, CORPUS CHRISTI, TX 78415 (NAICS 423310). OSHA activity number 342409133.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SOUTH TEXAS MOULDING, INC.
- Site address
- 6525 AYERS STREET
- City
- CORPUS CHRISTI
- State
- TX
- ZIP
- 78415
- Mailing
- P.O. BOX 271123, CORPUS CHRISTI, TX 78427
What kind of inspection was it?
- Inspection type
- Follow-up (F)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423310
- Employees
- 8
- Ownership type
- A
Citations
3 citations on file for this inspection.
1904.40 A
- Issued
- Oct 11, 2017
- Penalty
- Initial $2,535 · Current $1,000 Reduced
General-duty citation text
29 CFR 1904.40(a): The employer did not provide an authorized government representative the records within the four business hours: On or about June 20, 2017, at this facility, the employer did not provide within four (4) calendar working hours the requested records, such as, but not limited to: a. OSHA Form 300 for the calendar years 2016 and 2017, and b. OSHA Form 300A for the calendar year 2016. South Texas Moulding, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1904.40(a), which was contained in OSHA inspection number 1156792, citation number 02, item number 001 and was affirmed as a final order on September 14, 2016, with respect to a workplace located at 6525 Ayers Street, Corpus Christi, Texas 78415.
Recent events (2)
- — I (R) $1000
- — Z (R) $2535
1910.157 E03
- Issued
- Oct 11, 2017
- Abate by
- Oct 30, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: In the overstock warehouse, portable fire extinguishers were not annually inspected to ensure fire extinguishers operated effectively and safely at the following locations: a. the Koorsen fire extinguisher located on the Toyota Forklift Truck with serial number 63915, b. the Koorsen fire extinguisher located on the Toyota Forklift Truck with serial number 72197, and c. the Kidde Multipurpose Dry Chemical fire extinguisher No. AF-721806 in the west corner of the overstock warehouse.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 B01 II
- Issued
- Oct 11, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: In the main warehouse, the Square D electrical box did not have a knockout installed.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at South Texas Moulding, INC.
View South Texas Moulding, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 423310)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342409133.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.