WILLIAMSVILLE, NY —
OSHA Inspection: EMILIANO GELDRES
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of EMILIANO GELDRES in 408 MILL STREET, WILLIAMSVILLE, NY 14221 (NAICS 238130). OSHA activity number 342409661.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EMILIANO GELDRES
- Site address
- 408 MILL STREET
- City
- WILLIAMSVILLE
- State
- NY
- ZIP
- 14221
- Mailing
- 95 14TH STREET, BUFFALO, NY 14213
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 4
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.21 B02
- Issued
- Jun 30, 2017
- Abate by
- Aug 2, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
9 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: a) On or about 1/11/17 on the jobsite where a 3- story apartment building was under construction at 408 Mill St., Williamsville,NY: Employees engaged in construction work including framing and carpentry work, were not trained to recognize potential hazards on this type of jobsite, including but not limited to falls from roofs, decks /balconies, wall openings, ladders, skylights, stairs & scaffolds, electrical hazards, unguarded tools/machines, fire hazards, and the need for personal protective equipment to protect them from various hazards. They also were not trained in the applicable OSHA regulations to control or eliminate these hazards. ABATEMENT DOCUMENTATION REQUIRED
Recent events (1)
- — Z (S) $3803
1926.502 B03
- Issued
- Jun 30, 2017
- Penalty
- Initial $3,803 · Current $3,803
General-duty citation text
29 CFR 1926.502(b)(3): Guardrail systems were not capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied within 2 inches (5.1 cm) of the top edge, in any outward or downward direction, at any point along the top edge: a) On or about 1/11/17 on the exterior deck/balcony of unit 313 and other second and third story exterior decks/balconies of a 3- story apartment building under construction at 408 Mill St., Williamsville,NY: Temporary wood guardrails were installed along the two open sides of the decks/balconies to protect workers from falls of approx. 11 ft. from second story exterior decks /balconies to approx. 21 ft. 6 in. from third story exterior decks/balconies. On the unit 313 deck/balcony, the guardrail system consisted of one vertical 6 x 6 inch wood structural post in the northeast corner, one vertical wood 2x 4 nailed into the wall of the mechanical room at the northwest corner of the deck/balcony, and one vertical wood 2x 4 nailed into the wall of the building at the southeast corner of the deck/balcony. Horizontal wood 2 x 4 toprails, and horizontal wood 2 x 4 midrails were nailed into the vertical members to form the guardrail system . The horizontal spans of the toprails and midrails on the outside end of the deck /balcony were approx. 11 feet 4 inches. The horizontal spans of the toprails and midrails on the east sides of the deck/balcony were approx. 9 feet 3 inches. The horizontal spans on the toprails and midrails of unit 313 deck/balcony and all other decks/balconies were greater than the 8 foot span between vertical posts recommended for wooden guardrails in Appendix B of Subpart M of this standard. Additionally, all the top and mid rails were nailed on the outside of the vertical posts of the unit 313 deck/balcony and most of the other decks/balconies. Some decks/balconies had top and/or midrails that had failed ,were missing, or had been spliced . Most decks /balconies had identical dimensions. An employee fell 21 ft. 6 in. when both the top and midrail failed on the north end of the unit 313 deck/balcony. NO ABATEMENT DOCUMENTATIOM REQUIRED
Recent events (1)
- — Z (S) $3803
1926.502 B05
- Issued
- Jun 30, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(b)(5): Midrails, screens, mesh, intermediate vertical members, solid panels, and equivalent structural members were not capable of withstanding, without failure, a force of at least 150 pounds (666 N) applied in any downward or outward di a) On or about 1/11/17 on the exterior deck/balcony of unit 313 and other second and third story exterior decks/balconies of a 3- story apartment building under construction at 408 Mill St., Williamsville,NY: Temporary wood guardrails were installed along the two open sides of the decks/balconies to protect workers from falls of approx. 11 ft. from second story exterior decks /balconies to approx. 21 ft. 6 in. from third story exterior decks/balconies. On the unit 313 deck/balcony, the guardrail system consisted of one vertical 6 x 6 inch wood structural post in the northeast corner, one vertical wood 2x 4 nailed into the wall of the mechanical room at the northwest corner of the deck/balcony, and one vertical wood 2x 4 nailed into the wall of the building at the southeast corner of the deck/balcony. Horizontal wood 2 x 4 toprails, and horizontal wood 2 x 4 midrails were nailed into the vertical members to form the guardrail system . The horizontal spans of the toprails and midrails on the outside end of the deck /balcony were approx. 11 feet 4 inches. The horizontal spans of the toprails and midrails on the east sides of the deck/balcony were approx. 9 feet 3 inches. The horizontal spans on the toprails and midrails of unit 313 deck/balcony and all other decks/balconies were greater than the 8 foot span between vertical posts recommended for wooden guardrails in Appendix B of Subpart M of this standard. Additionally, all the top and mid rails were nailed on the outside of the vertical posts of the unit 313 deck/balcony and most of the other decks/balconies. Some decks/balconies had top and/or midrails that had failed ,were missing, or had been spliced . Most decks /balconies had identical dimensions. An employee fell 21 ft. 6 in. when both the top and midrail failed on the north end of the unit 313 deck/balcony. NO ABATEMENT DOCUMENTATIOM REQUIRED
Recent events (1)
- — Z (S) $0
More inspections in this industry (NAICS 238130)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342409661.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.