OSHA Inspection: EMILIANO GELDRES

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of EMILIANO GELDRES in 408 MILL STREET, WILLIAMSVILLE, NY 14221 (NAICS 238130). OSHA activity number 342409661.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Emiliano Geldres — free Get an email when a new federal OSHA severe-injury report for Emiliano Geldres is published. One employer, no account, unsubscribe in one click.
Establishment
EMILIANO GELDRES
Site address
408 MILL STREET
City
WILLIAMSVILLE
State
NY
ZIP
14221
Mailing
95 14TH STREET, BUFFALO, NY 14213
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.21 B02

Serious Gravity 10 1 instance 4 exposed
Issued
Jun 30, 2017
Abate by
Aug 2, 2017
Penalty
Initial $3,803 · Current $3,803
9 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:   a) On or about 1/11/17 on the jobsite  where  a 3- story apartment building was under construction at 408 Mill St., Williamsville,NY:  Employees  engaged in construction work including framing and carpentry work, were not trained to recognize potential hazards on this type of jobsite,  including but not limited to falls from roofs, decks /balconies, wall openings,  ladders, skylights,  stairs & scaffolds, electrical hazards, unguarded tools/machines, fire hazards, and the need for personal protective equipment to protect them from various hazards. They also were not trained in the applicable OSHA regulations to control or eliminate these hazards.    ABATEMENT  DOCUMENTATION  REQUIRED
Recent events (1)
  • — Z (S) $3803

1926.502 B03

Serious Gravity 10 1 instance 4 exposed
Issued
Jun 30, 2017
Penalty
Initial $3,803 · Current $3,803
29 CFR 1926.502(b)(3): Guardrail systems were not capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied within 2 inches (5.1 cm) of the top edge, in any outward or downward direction, at any point along the top edge:   a) On or about 1/11/17 on the exterior deck/balcony of unit 313 and other second and third story exterior decks/balconies of a 3- story apartment building under construction at 408 Mill St., Williamsville,NY:  Temporary  wood guardrails were installed  along the two open sides of the decks/balconies  to protect workers from falls of approx.  11 ft.  from second story exterior decks /balconies to approx.  21 ft. 6 in. from third story exterior decks/balconies.  On the unit 313 deck/balcony, the guardrail system consisted of one vertical 6 x 6 inch wood structural post in the northeast corner, one vertical wood  2x 4 nailed into the wall of the mechanical room at the northwest corner of the deck/balcony, and one vertical wood  2x 4 nailed into the wall of the building at the southeast corner of the deck/balcony.  Horizontal wood 2 x 4 toprails, and horizontal wood 2 x 4 midrails were nailed into the vertical members  to form the guardrail system .  The horizontal spans of the toprails and midrails on the outside end  of the deck /balcony were approx.  11 feet  4 inches. The horizontal spans of the toprails and midrails on the east  sides of the deck/balcony were approx.  9 feet 3 inches. The horizontal spans  on the toprails and midrails of unit 313 deck/balcony and all other decks/balconies  were greater  than the 8 foot  span between vertical posts  recommended  for wooden guardrails in Appendix  B of  Subpart M of this standard.  Additionally, all the top and mid rails were nailed on the outside of the vertical posts of the unit 313 deck/balcony and most of the other decks/balconies.  Some decks/balconies had top and/or midrails that had failed ,were missing, or had been spliced . Most decks /balconies had identical dimensions.   An employee fell   21 ft. 6 in. when both the top and midrail failed on the north end of the unit 313 deck/balcony.       NO ABATEMENT DOCUMENTATIOM REQUIRED
Recent events (1)
  • — Z (S) $3803

1926.502 B05

Serious Gravity 10 1 instance 4 exposed
Issued
Jun 30, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.502(b)(5): Midrails, screens, mesh, intermediate vertical members, solid panels, and equivalent structural members were not capable of withstanding, without failure, a force of at least 150 pounds (666 N) applied in any downward or outward di   a) On or about 1/11/17 on the exterior deck/balcony of unit 313 and other second and third story exterior decks/balconies of a 3- story apartment building under construction at 408 Mill St., Williamsville,NY:  Temporary  wood guardrails were installed  along the two open sides of the decks/balconies  to protect workers from falls of approx.  11 ft.  from second story exterior decks /balconies to approx.  21 ft. 6 in. from third story exterior decks/balconies.  On the unit 313 deck/balcony, the guardrail system consisted of one vertical 6 x 6 inch wood structural post in the northeast corner, one vertical wood  2x 4 nailed into the wall of the mechanical room at the northwest corner of the deck/balcony, and one vertical wood  2x 4 nailed into the wall of the building at the southeast corner of the deck/balcony.  Horizontal wood 2 x 4 toprails, and horizontal wood 2 x 4 midrails were nailed into the vertical members  to form the guardrail system .  The horizontal spans of the toprails and midrails on the outside end  of the deck /balcony were approx.  11 feet  4 inches. The horizontal spans of the toprails and midrails on the east  sides of the deck/balcony were approx.  9 feet 3 inches. The horizontal spans  on the toprails and midrails of unit 313 deck/balcony and all other decks/balconies  were greater  than the 8 foot  span between vertical posts  recommended  for wooden guardrails in Appendix  B of  Subpart M of this standard.  Additionally, all the top and mid rails were nailed on the outside of the vertical posts of the unit 313 deck/balcony and most of the other decks/balconies.  Some decks/balconies had top and/or midrails that had failed ,were missing, or had been spliced . Most decks /balconies had identical dimensions.   An employee fell   21 ft. 6 in. when both the top and midrail failed on the north end of the unit 313 deck/balcony.       NO ABATEMENT DOCUMENTATIOM REQUIRED